User manual XC-32 XC-320 XC-4200
VI.Rawtty and RemoteCOM
VI.1 - Introduction
Rawtty and RemoteCOM enable a server to use an Xcell asynchronous port as one of its
own ports. To perform this operation, you just have to install a driver on server and to
setup a few parameters on your Xcell.
VI.2 - RemoteCOM
RemoteCOM is a driver for Windows systems which enables you to redirect COM ports on
Xcell. RemoteCOM is made to manage flow control signals (DTR, DSR and DCD).
VI.2.1 - RemoteCOM under Windows 95/98
VI.2.1.1 - Setting up the Xcell
Only flow control parameter must be set on the Xcell.
Configuration example with Telnet console :
First, display current ports configuration :
ROOT>> serial show all
Port Mode Speed FlowCtrl LineC Cs Par. Stop ModemName Rtelnet
Time0
1 raw 9600 soft local 8 none 1 2001 0
2 raw 9600 soft local 8 none 1 2002 0
If you want to set hard flow control on ports 1 and 2, enter :
ROOT>> serial flowctrl hard 1 2
Then, reset ports with new parameters :
ROOT>> reset port 1 2
Display ports configuration again to see if new parameters are well set :
ROOT>> serial show all
Port Mode Speed FlowCtrl LineC Cs Par. Stop ModemName RtelnetTime0
1 raw 9600 hard local 8 none 1 2001 0
-37-