User manual XC-32 XC-320 XC-4200
1 raw 9600 soft local 8 none 1 2001 0
2 raw 9600 soft local 8 none 1 2002 0
If you want to set hard flow control on ports 1 and 2, enter :
ROOT>> serial flowctrl hard 1 2
Then, reset ports with new parameters :
ROOT>> reset port 1 2
Display ports configuration again to see if new parameters are well set :
ROOT>> serial show all
Port Mode Speed FlowCtrl LineC Cs Par. Stop ModemName Rtelnet
Time0
1 raw 9600 hard local 8 none 1 2001 0
2 raw 9600 hard local 8 none 1 2002 0
Speed, parity, csize and stop bit are send by RemoteCOM to the Xcell.
RemoteCOM transmits DTR signal and recepts states of DCD and DSR signals.
VI.2.2.2 - Installation of RemoteCOM driver
RemoteCOM for WINNT is composed of :
p
A service module: RemoteCOM(service).
p
A driver : RemoteCOM(driver).
p
A program for setup, audit and control of RemoteCOM service.
WARNING
: Do not mistake RemoteCOM service and RemoteCOM driver (that is also a
service). This one is automatically started and stopped by RemoteCOM service.
To install RemoteCOM, click on the "Setup" file of the installation disk/path.
p
Restart your system.
p
In the "
Start
" menu, click on :
p
Programs
->;
RemoteCOM
->;
RemoteCOM Administration
.
p
Click on "
Edit
" in the main menu.
p
Create : select "
Create
".
p
Enter XC's IP address (ex :
192.168.4.23
) , XC's port number (ex :
7
), WINDOWS
device (ex :
COM3
) and connection's parameters.
p
Change : select "
View&Modify
".
p
Delete : select "
Delete
".
-41-