MODE-1 is annunciated for 4-seconds after A.C. Power applied, where the Right 
Most LED flashes. Refer to the 

LED CHARGE MODE INDICATOR TABLE’

 and 

CHARGE MODE SETTING TABLE

.

 

o

 

‘Power On’ LED and Detection LED will illuminate to indicate that AC power 
is applied AND battery is in the process of being detected.

 

o

 

If the Red ‘Power On’ LED Flashes, it is indicating that the pending Charge 
Cycle  will  apply  a  special  charge  called  ‘Equalization  Charge’.  Refer  to 

Equalization Charge Cycle

 section for description of stage.

 

 

 

STAGE ONE – PRE-QUALIFICATION TEST 

o

 

Yellow  (Charging)  LED  flashes  slowly  (once  per  second)  to  test  battery. 
Charging stops if faults such as connection of 24v charger to a 36V battery 
pack or safety timers timed out, etc. Refer to ‘Troubleshooting Guide’ if an 
Error Code was displayed. 

o

 

Duration of this stage is dependent on condition of battery  – approximately 
10  seconds  under  average  circumstances,  but  if  your  battery  pack  was 
allowed to severely discharge to less than 1.75Vdc per cell (example  – 21v 
for a 24v battery), then the charger may take several hours of slow charging 
to try to slowly bring the battery up to above 1.75Vdc per cell. 

 

 

STAGE TWO – BULK CHARGE (Constant Current) 

o

 

Yellow  (Charging)  LED  illuminates  continuously  indicating  charging  at  full 
rated output. While charging, voltage is monitored for the occurrence of  the 
next charging stage. 

 

 

STAGE THREE – ABSORPTION CHARGE (Constant Voltage) 

o

 

Yellow (Charging) LED illuminated continuously. The charger now regulates 
at Absorption Voltage Level while monitoring charge current. 

o

 

Once  Charge  Current  has  decreased  to  a  sufficiently  low  level,  this  stage 
exits to the next stage. 

o

 

The Battery Pack has achieved approximately 95% State of Charge. 

 

 

STAGE FOUR – TOP OFF CHARGE STAGE 

o

 

Both Green (Charged) and Yellow (Charging) LEDs illuminate. 

o

 

Replenishing  last  5-10%  of  battery  capacity.  Charging  at  a  low  Constant 
Current rate, this stage monitors for time and dv/dt to terminate. 

o

 

The Battery Pack has achieved approximately 95% State of Charge. 

o

 

NOTE:

 If using a Charger MODE set to charge  a Flooded USBattery only, 

this stage may take up to 4 hours to complete. 

 

 

STAGE FIVE – EQUALIZATION CHARGE CYCLE

 

o

 

This  is  a  special  charge  condition  that  is  selectively  applied  and  is  not 
typically applied to every battery, nor with every charge cycle. If it is applied, 
the  next  stage  becomes  Stage  Six.  If  not  applied,  then  the  next  stage 
becomes Stage Five. 

o

 

The  Red  ‘Power-On’  LED  will  flash  during  the  entire  cycle  in  which 
Equalization  Charge  Stage  has  been  invoked,  and  the  flashing  will  cease 
when charge has completed. 

 

 

Содержание Q-SERIES

Страница 1: ...48F017Ezz 48Vdc 17Adc SCR Line Frequency Design xRy 64F014Ezz 64Vdc 14Adc SCR Line Frequency Design xRy 72F012Ezz 72Vdc 12Adc SCR Line Frequency Design Input Definition x 1 120Vac 50 and or 60Hz x 2...

Страница 2: ...Y AND OPERATING INSTRUCTIONS AT ALL TIMES To reduce risk of battery explosion follow all safety instructions below and those published by the battery manufacturer Review cautionary markings on vehicle...

Страница 3: ...E THE RISK OF AN ELECTRIC SHOCK KEEP THE CHARGER DRY DO NOT EXPOSE IT TO RAIN OR WATER 3 A C AND UTILITY REQUIREMENTS The use of an improper extension cord could result in a risk of a fire or electric...

Страница 4: ...nce with the National Electrical Code and all local codes and ordinances WARNING IMPROPER CONNECTION OF THE EQUIPMENT GROUNDING CONDUCTOR CAN RESULT IN A RISK OF AN ELECTRIC SHOCK The conductor with i...

Страница 5: ...nt connecting the battery including inter battery connections Follow the wire connection from the Equipment or Vehicle s receptacle down to the first battery on both the positive and negative conducto...

Страница 6: ...075 125AH 2 450V 1 0 0 1 0 20 PsZ Cell Lead Acid AGM 125 175AH 2 450V 1 0 0 1 1 21 PsZ Cell Lead Acid AGM 200 250AH 2 450V 1 0 1 0 0 22 PsZ Cell Lead Acid AGM 300 350AH 2 450V 1 0 1 0 1 23 General GEL...

Страница 7: ...0 05 0 0 1 0 1 21 1 0 1 0 1 06 0 0 1 1 0 22 1 0 1 1 0 07 0 0 1 1 1 23 1 0 1 1 1 08 0 1 0 0 0 24 1 1 0 0 0 09 0 1 0 0 1 25 1 1 0 0 1 10 0 1 0 1 0 26 1 1 0 1 0 11 0 1 0 1 1 27 1 1 0 1 1 12 0 1 1 0 0 28...

Страница 8: ...ge current has decreased down to a targeted value which is dependent on many factors such as size type age and chemistry of battery Upon completion of this stage approximately 95 of total charge is de...

Страница 9: ...ccurs However all batteries regardless of chemistry self discharge at a rate that is proportional to ambient temperature meaning that if a battery sits on a table completely disconnected from all load...

Страница 10: ...Illuminates continuously when AC power present Refer to the section TROUBLESHOOTING if FLASHING but not when flashing during a Charge Cycle that includes Equalization Charge Stage Shutdown Red Illumin...

Страница 11: ...urrent o Yellow Charging LED illuminates continuously indicating charging at full rated output While charging voltage is monitored for the occurrence of the next charging stage STAGE THREE ABSORPTION...

Страница 12: ...ention according to the flash rate Slow Flash Charge cycle ended via peak voltage detection in the Top Off Charge stage Medium Flash Charge cycle ended via peak voltage detection in the Equalization C...

Страница 13: ...nk Five Menus are made available and are selectable via the Menu Select Button Annunciation Start Up Menu Charge Status And Output Display Charge Status And Input Display Error Code Display Charge Sta...

Страница 14: ...cted Additionally only the Vac is displayed and is for reference use by Tech Support only the value is not indicative of actual utility AC power ERROR CODE DISPLAY MENU o Display shows assume 24V Batt...

Страница 15: ...s an indicator that charging was terminated when A C Power was disconnected TSTg Testing product due to possibility of missing factory installed TestPassCode the product is trying to reconfigure itsel...

Страница 16: ...o Charger s Output DC Cable connection is possibly connected to a battery pack with voltage higher than the output rating of the charger Battery Temperature Low High o If an external thermistor is con...

Страница 17: ...w to charge Batt Temperature Sensor Open Shorted o If a Battery Temperature Sensor Cable was installed at start of charging but then later found to be open or short circuited this error is produced In...

Страница 18: ...e but it is not this error is produced Check Inhibit vehicle wiring If correct internal inhibit switch may have been overload contact factory Also refer to the Lockout Inhibit Option Section for Exter...

Страница 19: ...d as a result of batteries left in lengthy storage without a trickle charge applied to it Try removing the output leads from the battery pack while A C Power is disconnected from the charger and recon...

Страница 20: ...ge temperature range of 40C to 125C It needs to be stored in clean dry conditions Medical Electrical Equipment needs special precautions regarding EMC and needs to be installed and put into service ac...

Страница 21: ...locate the two circuit pins that connect a Temperature Compensation Cable Temperature Compensation uses a temperature measuring device that is affixed to the battery pack and uses two conductors to c...

Страница 22: ...increased the 57 6V target to 58 8V When charging lead acid and many other chemistry types batteries during winter or cold climates or operating equipment in large Factory Freezer Applications a high...

Страница 23: ...as a circuit o Disconnect the output lead from the charger look inside the connector and count the number of circuits If there are 6 circuits then 2 of them are reserved for creating a Lockout Inhibit...

Страница 24: ...ay mirrors the Charger LED Display with one exception If an LED pattern flashes from the center LED out in a repeating pattern the Port is annunciating a Lost Communications error Check wiring for con...

Страница 25: ...25 15 Q SERIES SCHEMATIC KITS MOUNTING Q SERIES MOUNTING AND MECHANICAL PRODUCT DIMENSIONS LED Version Shown PRODUCT MOUNTING PATTERN FOOTPRINT...

Страница 26: ...26 Q SERIES SCHEMATIC Q SERIES REPAIR AND REPLACEMENT KITS...

Страница 27: ...cluded 11 12 KITS0187 Front Panel LED Label P Clamp Lockout CVP via Bushing Cable Bushing 2 3 4 6 15 KITS0188 Front Panel LCD Label Cable Bushing P Clamp Lockout CVP via Bushing 2 3 4 6 15 KITS0191 Pl...

Страница 28: ...28 16 R SERIES SCHEMATIC KITS MOUNTING R SERIES SCHEMATIC R SERIES REPAIR AND REPLACEMENT KITS...

Страница 29: ...lay Fuse PCB Module 12 13 KITS0174 A C Input 230V IEC Relay Fuse PCB Module 12 13 KITS0202 D C Output Connector with nut 2ccts installed Battery Leads Only 4 KITS0203 D C Output Connector with nut 3cc...

Страница 30: ...30 R SERIES MOUNTING AND MECHANICAL PRODUCT DIMENSIONS LCD VERSION SHOWN PRODUCT MOUNTING PATTERN FOOTPRINT...

Страница 31: ...n 813mm Cable SB175 Red OPCJ0064 L000813 Output DC Cable 108 0in 2743mm Cable SB175 Red OPCJ0064 L002743 Output DC Cable 108 0in 2743mm Cable SB350 Red OPCJ0065 L002743 Output DC Cable 108 0in 2743mm...

Страница 32: ...cated under the front label bottom left corner and a PC two to ten years of charge history data is available and records events such as battery over discharged thermal runaway events complete and inco...

Страница 33: ...ed or damaged or improperly or negligently used connected maintained or operated in any manner contrary to the instructions stated in this manual or affixed to the product s enclosure Repair or replac...

Отзывы: