Installing the XW Automatic Generator Start
975-0307-01-01
2–13
Type 5
Type 5 is a three-wire StartStop configuration that uses relay 3 to provide
the preheat signal for Generac’s Guardian Diesel generators.
Figure 2-7
Type 5 Connection Diagram
For additional information, see
“Circuit Limitations” on page 2–5.
XW AGS Harness Wires
Generator Wires
18
17
16
14
13
12
20
19
FUEL PRIME (PREHEAT)
12V GENERATOR B
Relay 1
Relay 3
Relay 2
5A fuse
5A fuse
5A fuse
GENERATOR RUN SIGNAL
STOP/PREHEAT
START
GENERATOR BATTERY NEGATIVE (–)
Table 2-8
Type 5 Relay and Timing Preset Configurations
Relay Function
Preset Configuration Setting
Relay 1 mode
StartStop
Relay 3 mode
Preheat
Gen Run signal hold time
2 s
Preheat time
15 s
Preheat to crank delay
2 s
Crank time
15 s
Crank retry time
15 s
Gen Cool Down
30 s
Shutdown bypass time
0 s
Start tries
3