background image

Warranty and Return Information

WA–2

975-0376-01-01

What proof of purchase is required?

In any warranty claim, dated proof of purchase must 

accompany the product and the product must not have been disassembled or modified without prior 
written authorization by Xantrex. 
Proof of purchase may be in any one of the following forms:

The dated purchase receipt from the original purchase of the product at point of sale to the end 
user; or

The dated dealer invoice or purchase receipt showing original equipment manufacturer (OEM) 
status; or

The dated invoice or purchase receipt showing the product exchanged under warranty.

What does this warranty not cover?

Claims are limited to repair and replacement, or if in 

Xantrex's discretion that is not possible, reimbursement up to the purchase price paid for the product. 
Xantrex will be liable to you only for direct damages suffered by you and only up to a maximum 
amount equal to the purchase price of the product.
This Limited Warranty does not warrant uninterrupted or error-free operation of the product or cover 
normal wear and tear of the product or costs related to the removal, installation, or troubleshooting of 
the customer's electrical systems. This warranty does not apply to and Xantrex will not be responsible 
for any defect in or damage to:
a)

the product if it has been misused, neglected, improperly installed, physically damaged or altered, 
either internally or externally, or damaged from improper use or use in an unsuitable environment;

b)

the product if it has been subjected to fire, water, generalized corrosion, biological infestations, or 
input voltage that creates operating conditions beyond the maximum or minimum limits listed in 
the Xantrex product specifications including high input voltage from generators and lightning 
strikes;

c)

the product if repairs have been done to it other than by Xantrex or its authorized service centers 
(hereafter "ASCs"); 

d)

the product if it is used as a component part of a product expressly warranted by another 
manufacturer;

e)

the product if its original identification (trade-mark, serial number) markings have been defaced, 
altered, or removed;

f)

the product if it is located outside of the country where it was purchased; and

g)

any consequential losses that are attributable to the product losing power whether by product 
malfunction, installation error or misuse.

Disclaimer

Product

THIS LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY PROVIDED BY XANTREX IN 
CONNECTION WITH YOUR XANTREX PRODUCT AND IS, WHERE PERMITTED BY LAW, IN LIEU OF ALL OTHER 
WARRANTIES, CONDITIONS, GUARANTEES, REPRESENTATIONS, OBLIGATIONS AND LIABILITIES, EXPRESS 
OR IMPLIED, STATUTORY OR OTHERWISE IN CONNECTION WITH THE PRODUCT, HOWEVER ARISING 
(WHETHER BY CONTRACT, TORT, NEGLIGENCE, PRINCIPLES OF MANUFACTURER'S LIABILITY, OPERATION 
OF LAW, CONDUCT, STATEMENT OR OTHERWISE), INCLUDING WITHOUT RESTRICTION ANY IMPLIED 
WARRANTY OR CONDITION OF QUALITY, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. 
ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT 
REQUIRED UNDER APPLICABLE LAW TO APPLY TO THE PRODUCT SHALL BE LIMITED IN DURATION TO THE 
PERIOD STIPULATED UNDER THIS LIMITED WARRANTY.

XPower_Inverter_5000_Owners_Guide.book  Page 2  Friday, April 4, 2008  2:59 PM

Содержание XPower 5000

Страница 1: ...by XPower Inverter 5000 Owner s Guide...

Страница 2: ...r Documentation UNLESS SPECIFICALLY AGREED TO IN WRITING XANTREX TECHNOLOGY INC XANTREX A MAKES NO WARRANTY AS TO THE ACCURACY SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED...

Страница 3: ...ers for this information This Guide does not provide installation instructions Installation should be handled by qualified installers including licensed technicians and electricians Qualified installe...

Страница 4: ...ooting the XPower Inverter 5000 Appendix A contains physical and electrical specifications of the XPower Inverter 5000 Conventions Used The following conventions are used in this guide Related Informa...

Страница 5: ...that wiring is in good condition adequately rated and not undersized Do not operate the XPower Inverter 5000 with damaged or substandard wiring 5 Do not operate the XPower Inverter 5000 if it has rec...

Страница 6: ...line powered machinery fuel tanks as well as joints fittings or other connections between components of the fuel system 4 Make sure the area around the battery is well ventilated 5 Never smoke or allo...

Страница 7: ...separate charger or transformer that is plugged into an AC receptacle and produces a low voltage charging output Some chargers for small rechargeable batteries can be damaged if connected to the XPow...

Страница 8: ...viii...

Страница 9: ...e of Use 1 2 Comprehensive Protection 1 2 2 Features AC Panel 2 2 DC Panel 2 4 Remote Switch 2 5 3 Operation Turning the Inverter On and Off 3 1 Operating Several Loads at Once 3 2 Display Screen 3 2...

Страница 10: ...shooting Common Problems 4 1 Buzz in Audio Equipment 4 1 Television Reception 4 1 Troubleshooting Reference 4 2 A Specifications Electrical Performance A 1 Physical Specifications A 2 Accessory A 2 Wa...

Страница 11: ...Vs light and heavy duty truck applications and other in vehicle applications The inverter provides up to 4000 W of continuous power It is designed to handle loads such as microwaves refrigerators free...

Страница 12: ...voltage drops below 10 5 V This feature will limit battery discharge High battery voltage shutdown Shuts the inverter down automatically if the input voltage rises to 15 5 V or more Overload and shor...

Страница 13: ...2 1 2 Features Chapter 2 Features describes the main features of the XPower Inverter 5000 Familiarize yourself with them before operating the inverter...

Страница 14: ...red indicates the inverter has shut down due to inverter overload over temperature under voltage over voltage AC output short circuit or AC back EMF backfeed protection shutdown 3 Power light green i...

Страница 15: ...AC output power 7 Remote On Off Switch Connector Port For connecting the Remote On Off Switch The remote switch and a 10 foot communications cable is included with the inverter 8 Two duplex GFCIs Each...

Страница 16: ...r sparks Risk of fire andexplosion Do not install near batteries in machinery space or area in which ignition protected equipmentis required Shock Hazard Do not open No serviceable parts inside INPUT...

Страница 17: ...s control circuit on and off This switch is not a power disconnect switch Disconnect DC power before working on any circuits connected to the inverter 2 Communications Cable is 10 feet 3 m long This...

Страница 18: ...2 6...

Страница 19: ...ry To turn the inverter on and off from the remote switch Move the On Off switch to the On position to turn the inverter on Move the On Off switch to the Off position to turn the inverter off When the...

Страница 20: ...ress the Display Function button The VOLTAGE CURRENT and AC POWER lights indicate what information the screen is showing Battery Voltage Indicator The BATTERY VOLTAGE INDICATOR indicates the DC voltag...

Страница 21: ...1 15 V Optimum Performance 12 0 13 0 V Low Voltage Alarm 11 0 V or less The audible low battery alarm sounds Low Voltage Shutdown less than 10 5 V The inverter shuts down to protect the battery from b...

Страница 22: ...rt the motor this low voltage condition may be why the motor won t start Make sure that the battery connections are good and that the battery is fully charged If the connections are good and the batte...

Страница 23: ...ust and dirt Recharging Your Batteries When possible recharge your batteries when they are about 50 discharged or earlier This gives the batteries a much longer life cycle than recharging when they ar...

Страница 24: ...3 6...

Страница 25: ...solution is to use a sound system that has a higher quality power supply Television Reception When the inverter is operating it can interfere with television reception on some channels If interference...

Страница 26: ...hutdown E05 warning code is ignored See possible causes under error 3 in this table See solution under error 5 in this table 2 E02 Flashing Fault LED Flashing Alarm Beeping Inverter is in overvoltage...

Страница 27: ...nder Voltage Warning Alarm is on Poor battery condition Poor DC wiring Charge the battery Install a new battery Use proper cable size and lengths and make solid connections For more information refer...

Страница 28: ...at cannot accurately read the RMS voltage of a modified sine wave Use a true RMS reading voltmeter such as the Fluke 87 10 N A Low output voltage on a true RMS reading voltmeter Low input voltage and...

Страница 29: ...ut not on the other then the GFCI protection on the outlet may have tripped Disconnect all loads and push the Reset button on the GFCI outlet Reconnect the load to the receptacle that was tripped and...

Страница 30: ...4 6...

Страница 31: ...0000 W Output power at 40 C 104 F ambient temperature and 12 Vdc input Maximum continuous output power 3500 W Max output current Continuous 5 minute rating 33 Aac 41 Aac Output voltage range 120 Vac R...

Страница 32: ...75 0376 01 01 Physical Specifications Accessory Length 18 1 2 47 cm Width 8 20 cm Height 6 1 4 16 cm Weight 24 1 lb 10 9 kg Remote On Off switch Part number 100 0830 01 01 On Off Switch with 10 foot c...

Страница 33: ...e parts or products of original or improved design in the repair or replacement If Xantrex repairs or replaces a product its warranty continues for the remaining portion of the original Warranty Perio...

Страница 34: ...the product if it has been subjected to fire water generalized corrosion biological infestations or input voltage that creates operating conditions beyond the maximum or minimum limits listed in the X...

Страница 35: ...Authorization Policy Before returning a product directly to Xantrex you must obtain a Return Material Authorization RMA number and the correct factory Ship To address Products must also be shipped pre...

Страница 36: ...se or incorrect installation if other conditions of the warranty have not been met or if no dated proof of purchase is available your unit may be serviced or replaced for a flat fee To return your pro...

Страница 37: ..._ Type of installation e g RV truck ___________________________ Length of time inverter has been installed ___________________________ Battery battery bank size ___________________________ Battery typ...

Страница 38: ...WA 6...

Отзывы: