background image

Troubleshooting

4–4

975-0376-01-01

8

E09

: Flashing

Fault LED: 
Flashing
Alarm: Beeping

Inverter’s DC 
terminal is in over 
temperature 
shutdown.

Loose connection 
between the inverter’s 
DC terminal and the DC 
input battery cable.

The DC input battery 
cable is undersized.

Tighten the connection at the 
terminal to a torque of 18–
20 ft-lbs (24–27 Nm)

Use the recommended size of 
battery cables. 
For more information, refer to 
“Selecting Cable Sizes” 
starting on page 2-6 of the 
Installation Guide.

9

N/A

Low output voltage
(96 VAC–104 
VAC)

You are using a 
voltmeter that cannot 
accurately read the RMS 
voltage of a modified 
sine wave.

Use a true RMS reading 
voltmeter such as the Fluke 
87.

10

N/A

Low output voltage
on a true RMS
reading voltmeter.

Low input voltage and 
the load is close to 
maximum allowable 
power.

Check the connections and 
DC cables and check if the 
battery is fully charged. 
Recharge the battery if it is 
low.

Reduce the load.

11

N/A

No AC output 
voltage; no DC 
input voltage 
indication.

The inverter is off.

No power to the inverter.

Battery disconnect 
switch or breaker is off.

Turn the inverter on.

Check if the DC cables are 
connected from battery to the 
inverter.

Close battery disconnect 
switch or breaker.

Table 4-1

Troubleshooting Reference

#

Error/Warning 
Code on Display

Problem

Possible Cause

Solution

XPower_Inverter_5000_Owners_Guide.book  Page 4  Friday, April 4, 2008  2:59 PM

Содержание XPower 5000

Страница 1: ...by XPower Inverter 5000 Owner s Guide...

Страница 2: ...r Documentation UNLESS SPECIFICALLY AGREED TO IN WRITING XANTREX TECHNOLOGY INC XANTREX A MAKES NO WARRANTY AS TO THE ACCURACY SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED...

Страница 3: ...ers for this information This Guide does not provide installation instructions Installation should be handled by qualified installers including licensed technicians and electricians Qualified installe...

Страница 4: ...ooting the XPower Inverter 5000 Appendix A contains physical and electrical specifications of the XPower Inverter 5000 Conventions Used The following conventions are used in this guide Related Informa...

Страница 5: ...that wiring is in good condition adequately rated and not undersized Do not operate the XPower Inverter 5000 with damaged or substandard wiring 5 Do not operate the XPower Inverter 5000 if it has rec...

Страница 6: ...line powered machinery fuel tanks as well as joints fittings or other connections between components of the fuel system 4 Make sure the area around the battery is well ventilated 5 Never smoke or allo...

Страница 7: ...separate charger or transformer that is plugged into an AC receptacle and produces a low voltage charging output Some chargers for small rechargeable batteries can be damaged if connected to the XPow...

Страница 8: ...viii...

Страница 9: ...e of Use 1 2 Comprehensive Protection 1 2 2 Features AC Panel 2 2 DC Panel 2 4 Remote Switch 2 5 3 Operation Turning the Inverter On and Off 3 1 Operating Several Loads at Once 3 2 Display Screen 3 2...

Страница 10: ...shooting Common Problems 4 1 Buzz in Audio Equipment 4 1 Television Reception 4 1 Troubleshooting Reference 4 2 A Specifications Electrical Performance A 1 Physical Specifications A 2 Accessory A 2 Wa...

Страница 11: ...Vs light and heavy duty truck applications and other in vehicle applications The inverter provides up to 4000 W of continuous power It is designed to handle loads such as microwaves refrigerators free...

Страница 12: ...voltage drops below 10 5 V This feature will limit battery discharge High battery voltage shutdown Shuts the inverter down automatically if the input voltage rises to 15 5 V or more Overload and shor...

Страница 13: ...2 1 2 Features Chapter 2 Features describes the main features of the XPower Inverter 5000 Familiarize yourself with them before operating the inverter...

Страница 14: ...red indicates the inverter has shut down due to inverter overload over temperature under voltage over voltage AC output short circuit or AC back EMF backfeed protection shutdown 3 Power light green i...

Страница 15: ...AC output power 7 Remote On Off Switch Connector Port For connecting the Remote On Off Switch The remote switch and a 10 foot communications cable is included with the inverter 8 Two duplex GFCIs Each...

Страница 16: ...r sparks Risk of fire andexplosion Do not install near batteries in machinery space or area in which ignition protected equipmentis required Shock Hazard Do not open No serviceable parts inside INPUT...

Страница 17: ...s control circuit on and off This switch is not a power disconnect switch Disconnect DC power before working on any circuits connected to the inverter 2 Communications Cable is 10 feet 3 m long This...

Страница 18: ...2 6...

Страница 19: ...ry To turn the inverter on and off from the remote switch Move the On Off switch to the On position to turn the inverter on Move the On Off switch to the Off position to turn the inverter off When the...

Страница 20: ...ress the Display Function button The VOLTAGE CURRENT and AC POWER lights indicate what information the screen is showing Battery Voltage Indicator The BATTERY VOLTAGE INDICATOR indicates the DC voltag...

Страница 21: ...1 15 V Optimum Performance 12 0 13 0 V Low Voltage Alarm 11 0 V or less The audible low battery alarm sounds Low Voltage Shutdown less than 10 5 V The inverter shuts down to protect the battery from b...

Страница 22: ...rt the motor this low voltage condition may be why the motor won t start Make sure that the battery connections are good and that the battery is fully charged If the connections are good and the batte...

Страница 23: ...ust and dirt Recharging Your Batteries When possible recharge your batteries when they are about 50 discharged or earlier This gives the batteries a much longer life cycle than recharging when they ar...

Страница 24: ...3 6...

Страница 25: ...solution is to use a sound system that has a higher quality power supply Television Reception When the inverter is operating it can interfere with television reception on some channels If interference...

Страница 26: ...hutdown E05 warning code is ignored See possible causes under error 3 in this table See solution under error 5 in this table 2 E02 Flashing Fault LED Flashing Alarm Beeping Inverter is in overvoltage...

Страница 27: ...nder Voltage Warning Alarm is on Poor battery condition Poor DC wiring Charge the battery Install a new battery Use proper cable size and lengths and make solid connections For more information refer...

Страница 28: ...at cannot accurately read the RMS voltage of a modified sine wave Use a true RMS reading voltmeter such as the Fluke 87 10 N A Low output voltage on a true RMS reading voltmeter Low input voltage and...

Страница 29: ...ut not on the other then the GFCI protection on the outlet may have tripped Disconnect all loads and push the Reset button on the GFCI outlet Reconnect the load to the receptacle that was tripped and...

Страница 30: ...4 6...

Страница 31: ...0000 W Output power at 40 C 104 F ambient temperature and 12 Vdc input Maximum continuous output power 3500 W Max output current Continuous 5 minute rating 33 Aac 41 Aac Output voltage range 120 Vac R...

Страница 32: ...75 0376 01 01 Physical Specifications Accessory Length 18 1 2 47 cm Width 8 20 cm Height 6 1 4 16 cm Weight 24 1 lb 10 9 kg Remote On Off switch Part number 100 0830 01 01 On Off Switch with 10 foot c...

Страница 33: ...e parts or products of original or improved design in the repair or replacement If Xantrex repairs or replaces a product its warranty continues for the remaining portion of the original Warranty Perio...

Страница 34: ...the product if it has been subjected to fire water generalized corrosion biological infestations or input voltage that creates operating conditions beyond the maximum or minimum limits listed in the X...

Страница 35: ...Authorization Policy Before returning a product directly to Xantrex you must obtain a Return Material Authorization RMA number and the correct factory Ship To address Products must also be shipped pre...

Страница 36: ...se or incorrect installation if other conditions of the warranty have not been met or if no dated proof of purchase is available your unit may be serviced or replaced for a flat fee To return your pro...

Страница 37: ..._ Type of installation e g RV truck ___________________________ Length of time inverter has been installed ___________________________ Battery battery bank size ___________________________ Battery typ...

Страница 38: ...WA 6...

Отзывы: