Operating Limits
975-0376-01-01
3–3
Operating Limits
Power Output
The
XPower Inverter 5000
can deliver up to 4000 W continuous and up to
5000 W for five minutes.
Input Voltage
The allowable inverter input (battery) voltage ranges are shown in the
following table:
Operating Condition
Voltage Range
Comment
Normal
11–15 V
Optimum
Performance
12.0–13.0 V
Low Voltage Alarm
11.0 V or less
The audible low battery alarm
sounds.
Low Voltage
Shutdown
less than 10.5 V
The inverter shuts down to protect the
battery from being over-discharged.
High Voltage
Shutdown
15.5 V or more
The inverter shuts down to protect
itself from excessive input voltage.
Note:
Although the inverter
incorporates over-voltage protection,
it can still be damaged if input
voltage exceeds 16 V.
High Voltage Alarm
15.0 V
The audible high voltage alarm
sounds.