Operating Limits
975-0263-01-01
4–5
Operating Limits
Power Output
The XM Series Inverter can deliver up to 1000 watts (XM 1000) or 1800
watts (XM 1800) continuous power. The wattage rating applies to
resistive loads such as incandescent lights.
Input Voltage
The allowable XM Series Inverter input voltage ranges are shown in the
following table:
Operating
Condition
Voltage Range
Comment
Normal
11–15.0 V
Optimum
Performance
12.0–13.0 V
Low Voltage Alarm
11.0 V or less
The low battery alarm beeps once
every two seconds and the display
shows fault code E01 alternating with
the battery voltage.
Low Voltage
Shutdown
Less than
10.5 V
The low battery alarm beeps every
second and the display shows fault
code E02 alternating with the battery
voltage. The status LED turns red and
the inverter shuts down to protect the
battery from being over-discharged.
High Voltage
Shutdown
15.5 V or more
The over-voltage alarm beeps every
second and the display shows fault
code E03 alternating with the battery
voltage. The status LED turns red and
the inverter shuts down to protect
itself from excessive input voltage.
Note:
Although the XM Series
Inverter incorporates over-voltage
protection, it can still be damaged if
input voltage exceeds 16 V.
Содержание Xantrex PRO XM 1000
Страница 2: ...Xantrex PRO Inverter Owner s Guide ...
Страница 13: ...xii ...
Страница 19: ...2 4 ...
Страница 51: ...4 8 ...
Страница 57: ...5 6 ...
Страница 60: ...Mounting Dimensions 975 0263 01 01 A 3 Mounting Dimensions Figure A 1 XM 1800 Mounting Dimensions ...
Страница 61: ...Specifications A 4 975 0263 01 01 Figure A 2 XM 1000 Mounting Dimensions ...
Страница 73: ...C 4 ...