Local Operation
3-18
M370078-01
Alarms and Errors
Several conditions can cause alarms in the XG. Some conditions are:
•
From user configurable features.
•
Controlled in hardware and will trigger regardless of configuration.
All alarms, with the exception of the Fan alarm, will result in the output of
the power supply being disabled. The Fan alarm does not affect the output.
When an alarm is triggered, the appropriate alarm message will begin
blinking on the display and the Alarm LED will be illuminated.It is
possible that more than one alarm will trigger at the same time. When this
occurs, the alarm with the highest precedence will blink on the display.
Table 3-4 lists the precedence of alarms. If the alarm is cleared and the
event which caused the alarm has not been corrected, then the alarm may
trigger again immediately. Fix the reason for the alarm before you clear it.
Table 3-4
Alarm Order of Precedence
Alarm
Precedence
Output
Latch
Maskable
Display
AC Fail
1 (Highest)
Yes
No
AC Fail
Over Temperature Protection (OTP)
2
Yes
Yes
O7P Pro
Fan
4
No
Yes
FAn Pro
Interlock
6
No
No
In Loc
Over Voltage Protection (OVP)
7
Always
No
OVP Pro
Over Current Protection (OCP)
8
Always
No
OCP pro
Foldback
9
Yes
Yes
FLD Pro
External Shutdown
10
No
Yes
SD POL
Under Voltage Protection (UVP)
11 (Lowest)
No
Yes
UUP Pro
Flash Checksum Failure
1
1.The Flash Checksum Failure alarms are an exception as they are a terminal alarm that can only
occur during boot up. It can only be cleared by doing a soft reset (losing the configuration of the
unit) or by power cycling the unit.
N/A
N/A
N/A
FLA FAIL
Содержание Watt Series Programmable DC Power Supply XG 850
Страница 2: ......
Страница 3: ...XG 850 Watt Series Programmable DC Power Supply Operating Manual...
Страница 6: ......
Страница 18: ...xvi...
Страница 30: ...1 8...
Страница 52: ...Local Operation 3 8 M370078 01 Figure 3 3 Front Panel Menu System...
Страница 82: ...Local Operation 3 38 M370078 01 The SCPI command s for these instructions are SYSTem channel s REMote STATe...
Страница 86: ...Local Operation 3 42 M370078 01 Figure 3 5 Split Supply Operation V V Common Power Supply Power Supply Load...
Страница 126: ...Analog Programming APG and Isolated Analog Programming ISOL 4 34 M370078 01...
Страница 198: ...5 72...
Страница 262: ...A 36...
Страница 284: ...IX 4...
Страница 285: ......