Device-Specific Error List
An error in the range [-399, 300] or [1, 32767] indicates that the
instrument has detected an error which is not a command error, a query
error, or an execution error; some device operations did not properly
complete, possibly due to an abnormal hardware or firmware condition.
These codes are also used for self-test response errors. The occurrence of
any error in the class causes the device-specific error bit (bit 3) in the
Event Status Register to be set.
-222
Data out of range
Indicates that a legal program data element was parsed but
could not be executed because the interpreted value was
outside the legal range as defined by the device
(see
IEEE
488.2
, 11.5.1.1.5)
-224
Illegal parameter value
Used where the exact value, from a list of possible values, was
expected.
-291
Out of memory
Used when the Autosequence programming buffer is full.
Table B-2
Execution Error List
Error Code Error Message Description
Table B-3
Device-Specific Error List
Error Code Error Message Description
-300
Device-specific error.
Indicates that the power supply could not complete the
operation due to some condition of the power supply.
-350
Queue Overflow
A specific code entered into the queue in lieu of the code that
caused the error. This code indicates that there is no room in the
queue and an error occurred but was not recorded.
-360
Communication error
This is the generic communication error for devices.
-363
Input buffer overrun
Software or hardware input buffer on serial port overflows with
data caused by improper or nonexistent pacing.
-365
Time out error
This is a generic device-dependent error.
Содержание Watt Series Programmable DC Power Supply XG 850
Страница 2: ......
Страница 3: ...XG 850 Watt Series Programmable DC Power Supply Operating Manual...
Страница 6: ......
Страница 18: ...xvi...
Страница 30: ...1 8...
Страница 52: ...Local Operation 3 8 M370078 01 Figure 3 3 Front Panel Menu System...
Страница 82: ...Local Operation 3 38 M370078 01 The SCPI command s for these instructions are SYSTem channel s REMote STATe...
Страница 86: ...Local Operation 3 42 M370078 01 Figure 3 5 Split Supply Operation V V Common Power Supply Power Supply Load...
Страница 126: ...Analog Programming APG and Isolated Analog Programming ISOL 4 34 M370078 01...
Страница 198: ...5 72...
Страница 262: ...A 36...
Страница 284: ...IX 4...
Страница 285: ......