Wiring to a Generator
975-0209-01-01
2–19
Auto Gen Start connections
The connections between the inverter/charger and the generator are made on the terminal
strip. All these components are located inside the AC compartment of the inverter. See
Figure 2-8.
Figure 2-8
RV Series Auto Gen Start terminal block
Terminal Name
Relay
Description
GEN STOP 2
Relay 1
normally open contact
GEN STOP 1
Relay 1
common contact
GEN STOP 3
Relay 1
normally closed contact
GEN START 2
Relay 2
normally open contact
GEN START 1
Relay 2
common contact
PREHEAT 1
Relay 3
normally open contact
PREHEAT 2
Relay 3
common contact
GEN RUN
n/a
Generator run signal input. This connection is required
for the inverter/charger to be able to detect when the
generator is running. For example, Power Tech supplies
a gray wire marked “12V power or +12V with engine
running.” This gray wire must connect to the GEN
RUN input.
THER
n/a
Thermostat 5V–30V input.
THERMOSTAT –
n/a
Thermostat return (ground)