Installation
975-0126-01-01
23
Connecting the AC Output Wires
To make the AC output wiring connections:
1. Remove one of the AC knockouts from the front or side of the unit using a
slot screwdriver. Do not leave the knockout inside the wiring compartment
2. Install a strain-relief clamp in the AC knockout.
3. Run the AC wiring through the strain-relief clamp.
4. Strip approximately 2 inches (50 mm) off the jacket from the AC cable and
separate the three wires..
5. Using an appropriate sized slot screwdriver, loosen the wire attachment
screws on the AC output terminals. Do not remove the screws.
6. Insert the line wire into "L", the neutral wire into "N", and the ground wire
into ground
, as shown in Figure 6. Observe the colour codes described in
Table 4.
7. Tighten the wire attachment screws. Leave some slack wire inside the wiring
box.
8. Secure the strain-relief clamp on the AC output cable jacket.
9. Attach the wiring compartment cover panel and tighten the four screws.
10. Connect the outgoing AC wires to an AC load panel equipped with circuit
breakers.
Figure 6
AC In and AC Out: Hardwiring Completed
CAUTION: Risk of equipment damage
Do not connect the output of the inverter to any incoming AC source.
Important:
The applicable installation code may not allow you to run the AC
input and AC output wiring through the same AC knockout.
Содержание RS2000
Страница 1: ...RS2000 Sine Wave Inverter Charger Installation Guide RS2000...
Страница 2: ......
Страница 3: ...RS2000 Sine Wave Inverter Charger Installation Guide...
Страница 8: ...iv 975 0126 01 01...
Страница 16: ...xii...
Страница 18: ...xiv...
Страница 49: ...Installation 975 0126 01 01 31 Figure 12 Connecting the BTS Cable to Battery Temp jack...
Страница 56: ...Installation 38 975 0126 01 01 Figure 15 Inverter Charger Dimensions...
Страница 75: ......