Fault Code Descriptions
152607
4–11
XX61
Right Matrix
Temperature
S
This fault indicates that the PV225S
has detected that the temperature of
the right IGBT matrix aluminum
heatsink has exceeded the maximum
allowed value of 95 °C.
•
Fuses F15 or F16 blown
•
External cooling fan
inoperable
•
Air flow on heat sink
impeded due to
accumulation of debris
•
Operation above rated
ambient temperature for
an extended period of
time
0070
Interlock Activated
H
This fault indicates that the PV225S
has detected that the door of the Main
Inverter Enclosure is open and the
door interlock switch is in the active
position. This fault is primarily for
personnel safety. Opening the door of
the Main Inverter Enclosure while the
PV225S is processing power will
cause an immediate orderly shutdown
of the system.
•
Door is open and
interlock switch is
active
•
Interlock switch is
inoperable
•
P2 or P3 on CCU2 is
loose or disconnected
•
CCU2 ±15Vdc Power
Supply is defective
0071
PV Switch Open
H
This fault indicates that the PV225S
has detected that the DC Disconnect
Switch (S2) is open and the auxiliary
switch is in the active position. This
fault is primarily for personnel safety.
Opening the DC disconnect switch
while the PV225S is processing
power will cause an immediate
orderly shutdown of the system.
•
DC disconnect switch is
open and auxiliary
switch is active
•
Auxiliary switch is
inoperable
•
P2 or P3 on CCU2 is
loose or disconnected
•
CCU2 ±15 Vdc Power
Supply is defective
0075
Shutdown Remotely
S
This fault indicates that the PV225S
has detected that the system was
commanded via the GUI to transition
to the Shutdown State. This fault is
not indicative of a failure or
malfunction, but primarily used to
disable the system remotely.
•
Remote Shutdown
command via the GUI
Table 4-1
Fault Codes
Error
Code Fault
Source(s)
Fault Type
H=Hardware
S=Software
Fault Description
Possible Causes
Содержание PV225S-480-P
Страница 1: ...PV225S 225 kW Grid Tied Photovoltaic Inverter PV225S 480 P Operation and Maintenance Manual...
Страница 2: ......
Страница 3: ...PV225S 225 kW Grid Tied Photovoltaic Inverter Operation and Maintenance Manual...
Страница 8: ...vi...
Страница 14: ...xii...
Страница 22: ...xx...
Страница 78: ...2 38...
Страница 79: ...Computer Communications with the PV225S 152607 2 39...
Страница 80: ...Operation 2 40 152607...
Страница 88: ...3 8...
Страница 102: ...4 14...
Страница 107: ...Maintenance Safety 152607 5 5 Figure 5 3 PV Terminal Locations PV NEGative K2 6T3 PV POSitive S2 6 PV GrouND TB4...
Страница 110: ...5 8...
Страница 115: ...Appendix A Schematics 152607 A 5 Figure A 1 Electrical Diagram sample...
Страница 122: ...WA 4...
Страница 125: ......