background image

©2000 Xantrex Technology Inc.

Changes in Manual:

Page-1, 5, 34, 39 and 119–All references to software version 4.01 should now read 

4.10

.

Page 1 and 17–

The SW4024, SW4048 and SW5548 inverter models are UL listed to

UL1741-First Edition which incorporates IEEE929 recommended practices.

Labeling

Page 7 and 12–The product rating labels have changed as shown below to reflect the UL listing:

QUARTER

DATE MFD

1

2

3

XANTREX TECHNOLOGY - USA PATENT No. 5,373,433
5916 195TH ST. N.E.  ARLINGTON, WA. 98223  USA
www.traceengineering.com

YEAR

4

01

00

03

02

05

04

 SW4048

MODEL:

SW4048____

      ------ INVERTER SYSTEM ------
MAX CONTINUOUS AC OUTPUT POWER:  4000 VA
NOMINAL BATTERY BANK VOLTAGE:  48 VDC
NOMINAL DC OPERATING VOLTAGE:  50.4 VDC
RANGE OF OPERATING DC VOLTAGE:  44-66 VDC
MAX OPERATING DC CURRENT:  100 AMPS DC
MAX SHORT CIRCUIT DC CURRENT:  400 AMPS DC
NOMINAL AC OUTPUT VOLTAGE:  120 VAC
NOMINAL AC OUTPUT FREQUENCY:  60 HZ
MAX CONTINUOUS AC OUTPUT CURRENT:  33.3 AMPS AC
MAX AC OUTPUT OVERCURRENT PROTECTION:  35 AMPS AC
MAX OUTPUT FAULT AC CURRENT:  78 AMPS AC RMS

      ------ BATTERY CHARGER SYSTEM ------
NOMINAL AC INPUT VOLTAGE:  120 VAC
OPERATING FREQUENCY RANGE:   54-66 HZ
MAX CONTINUOUS BATTERY CHARGER AC CURRENT:  30 AMPS AC
MAX CONTINUOUS BATTERY CHARGER DC CURRENT:  60 AMPS DC
MAX CONTINUOUS BATTERY CHARGER INPUT VA:  3600 VA
TYPICAL BATTERY CHARGER POWER FACTOR: 0.9 TO 1.0
MAX AC TRANSFER SWITCH INPUT CURRENT:  60 AMPS AC

    ---- UTILITY INTERACTIVE SYSTEM ----
OPERATING AC INPUT VOLTAGE RANGE:  106-132 VAC
OPERATING FREQUENCY RANGE  (AC1):  59.3-60.5 HZ
MAX UTILITY AC BACKFEED CURRENT:  0 AMPS AC
MAX CONTINUOUS AC OUTPUT POWER:  4000 VA
OPERATING  POWER FACTOR: 0.9 TO 1.0

1

1

1

270-0032-01-01

NON-ISLANDING
UTILITY INTERACTIVE INVERTER
WITH INTEGRAL TRANSFORMER
ISOLATION

POWER INVERTER/CHARGER
LISTED FOR CANADA
CAN/CSA-C22.2 No. 107.1-95

POWER INVERTER/CHARGER
STANDARD UL1741-1999
1st EDITION

55CL

39FL

270-0032-01-01

QUARTER

DATE MFD

1

2

3

XANTREX TECHNOLOGY - USA PATENT No. 5,373,433
5916 195TH ST. N.E.  ARLINGTON, WA. 98223  USA
www.traceengineering.com

YEAR

4

01

00

03

02

05

04

SW4024

MODEL:

SW4024____

      ------ INVERTER SYSTEM ------
MAX CONTINUOUS AC OUTPUT POWER:  4000 VA
NOMINAL BATTERY BANK VOLTAGE:  24 VDC
NOMINAL DC OPERATING VOLTAGE:  25.2 VDC
RANGE OF OPERATING DC VOLTAGE:  22-32 VDC
MAX OPERATING DC CURRENT:  200 AMPS DC
MAX SHORT CIRCUIT DC CURRENT:  800 AMPS DC
NOMINAL AC OUTPUT VOLTAGE:  120 VAC
NOMINAL AC OUTPUT FREQUENCY:  60 HZ
MAX CONTINUOUS AC OUTPUT CURRENT:  33.3 AMPS AC
MAX AC OUTPUT OVERCURRENT PROTECTION:  35 AMPS AC
MAX OUTPUT FAULT AC CURRENT:  78 AMPS AC RMS

      ------ BATTERY CHARGER SYSTEM ------
NOMINAL AC INPUT VOLTAGE:  120 VAC
OPERATING FREQUENCY RANGE:   54-66 HZ
MAX CONTINUOUS BATTERY CHARGER AC CURRENT:  30 AMPS AC
MAX CONTINUOUS BATTERY CHARGER DC CURRENT:  110 AMPS DC
MAX CONTINUOUS BATTERY CHARGER INPUT VA:  3600 VA
TYPICAL BATTERY CHARGER POWER FACTOR: 0.9 TO 1.0
MAX AC TRANSFER SWITCH INPUT CURRENT:  60 AMPS AC

    ---- UTILITY INTERACTIVE SYSTEM ----
OPERATING AC INPUT VOLTAGE RANGE:  106-132 VAC
OPERATING FREQUENCY RANGE  (AC1):  59.3-60.5 HZ
MAX UTILITY AC BACKFEED CURRENT:  0 AMPS AC
MAX CONTINUOUS AC OUTPUT POWER:  4000 VA
OPERATING  POWER FACTOR: 0.9 TO 1.0

1

1

1

270-0033-01-01

NON-ISLANDING
UTILITY INTERACTIVE INVERTER
WITH INTEGRAL TRANSFORMER
ISOLATION

POWER INVERTER/CHARGER
LISTED FOR CANADA
CAN/CSA-C22.2 No. 107.1-95

POWER INVERTER/CHARGER
STANDARD UL1741-1999
1st EDITION

55CL

39FL

270-0033-01-01

2

ADDENDUM

QUARTER

DATE MFD

1

2

3

XANTREX TECHNOLOGY - USA PATENT No. 5,373,433
5916 195TH ST. N.E.  ARLINGTON, WA. 98223  USA
www.traceengineering.com

YEAR

4

01

00

03

02

05

04

 SW5548

MODEL:

SW5548____

270-0031-01-01

      ------ INVERTER SYSTEM ------
MAX CONTINUOUS AC OUTPUT POWER:  5500 VA
NOMINAL BATTERY BANK VOLTAGE:  48 VDC
NOMINAL DC OPERATING VOLTAGE:  50.4 VDC
RANGE OF OPERATING DC VOLTAGE:  44-66 VDC
MAX OPERATING DC CURRENT:  140 AMPS DC
MAX SHORT CIRCUIT DC CURRENT:  400 AMPS DC
NOMINAL AC OUTPUT VOLTAGE:  120 VAC
NOMINAL AC OUTPUT FREQUENCY:  60 HZ
MAX CONTINUOUS AC OUTPUT CURRENT:  45.8 AMPS AC
MAX AC OUTPUT OVERCURRENT PROTECTION:  50 AMPS AC
MAX OUTPUT FAULT AC CURRENT:  78 AMPS AC RMS

      ------ BATTERY CHARGER SYSTEM ------
NOMINAL AC INPUT VOLTAGE:  120 VAC
OPERATING FREQUENCY RANGE:   54-66 HZ
MAX CONTINUOUS BATTERY CHARGER AC CURRENT:  35 AMPS AC
MAX CONTINUOUS BATTERY CHARGER DC CURRENT:  70 AMPS DC
MAX CONTINUOUS BATTERY CHARGER INPUT VA:  4200 VA
TYPICAL BATTERY CHARGER POWER FACTOR: 0.9 TO 1.0
MAX AC TRANSFER SWITCH INPUT CURRENT:  60 AMPS AC

    ---- UTILITY INTERACTIVE SYSTEM ----
OPERATING AC INPUT VOLTAGE RANGE:  106-132 VAC
OPERATING FREQUENCY RANGE  (AC1):  59.3-60.5 HZ
MAX UTILITY AC BACKFEED CURRENT:  0 AMPS AC
MAX CONTINUOUS AC OUTPUT POWER:  5500 VA
OPERATING  POWER FACTOR: 0.9 TO 1.0

1

1

1

NON-ISLANDING
UTILITY INTERACTIVE INVERTER
WITH INTEGRAL TRANSFORMER
ISOLATION

POWER INVERTER/CHARGER
LISTED FOR CANADA
CAN/CSA-C22.2 No. 107.1-95

POWER INVERTER/CHARGER
STANDARD UL1741-1999
1st EDITION

55CL

39FL

270-0031-01-01

Mounting

The second paragraph under “MOUNTING” should read as follows:

“Use 1/4" minimum bolts for mounting. The mounting must capable of supporting 

four times

 the

weight of the inverter...”

Add the following to the second paragraph:

When mounting to a vertical surface, such as a wall, ensure the inverter (or backing

material) is securely mounted to the wall studs for proper support.

Vertical wall mounting with proper access panels in place is the only UL approved

mounting method for fire prevention.

Содержание PLUS SW4024

Страница 1: ... 2000 Xantrex Technology Inc Addendum to the Installation and Operator s Manual for SW4024 SW4048 SW5548 Models Only SW Series ã2000 Xantrex 976 0013 01 01 Rev A 11 00 TM ...

Страница 2: ... 2000 Xantrex Technology Inc ...

Страница 3: ...y voltage limits programmed in SET INPUT LOWER UPPER LIMIT VAC menu item located under MENU HEADING 11 for input AC1 are displayed but ignored when the SELL mode is selected The SELL frequency window is nonadjustable and locked at 59 3 60 5 Hz anytime the inverter is in SELL mode This is indicated by the LINE TIE LED ON For any voltage or frequency condition outside these specified operating windo...

Страница 4: ...VAC OPERATING FREQUENCY RANGE 54 66 HZ MAX CONTINUOUS BATTERY CHARGER AC CURRENT 30 AMPS AC MAX CONTINUOUS BATTERY CHARGER DC CURRENT 110 AMPS DC MAX CONTINUOUS BATTERY CHARGER INPUT VA 3600 VA TYPICAL BATTERY CHARGER POWER FACTOR 0 9 TO 1 0 MAX AC TRANSFER SWITCH INPUT CURRENT 60 AMPS AC UTILITY INTERACTIVE SYSTEM OPERATING AC INPUT VOLTAGE RANGE 106 132 VAC OPERATING FREQUENCY RANGE AC1 59 3 60 ...

Страница 5: ... inverter is between 88 to 110 of nominal AC line voltage Display Deletions The following menu display items have been deleted for various reasons unrelated to UL requirements Under the ERROR CAUSES 5 menu heading menu item INVERTER BREAKER TRIPPED has been deleted Under the GENERATOR MODE 2 menu heading menu item GEN MAX RUN TIME ERROR has been deleted Under the GENERATOR MODE 2 menu heading all ...

Страница 6: ... to island conditions As a result active control techniques have been incorporated into the SW inverter for detecting potential dispersed generation islands A utility wishing to ensure against renewable energy supported dispersed generation islanding may require the use of a non islanding inverter Trace has designed the new software protection system to comply with the requirements of the non isla...

Страница 7: ... 2000 Xantrex Technology Inc ...

Страница 8: ...visit our website at www traceengineering com 5916 195th Street N E Arlington WA 98223 Phone 360 435 8826 Fax 360 435 2229 ...

Отзывы: