Electrical Specifications
975-0334-01-01
A–5
Efficiency
GT4.0N-NA-240/208 UL-05
GT4.0-NA-240/208 UL-05
GT4.0-NA-240/208-POS UL-05
Output voltage
240 V
208 V
240 V
208 V
Maximum efficiency 96%
95.7%
95.9%
95.6%
CEC efficiency
95.5%
95%
95%
95%
Night-time tare loss
1 W
Figure A-2
GT4.0N Typical Efficiency
Figure A-3
GT4.0 Typical Efficiency
4kW Efficiency vs Output Power
89
90
91
92
93
94
95
96
97
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
% of Rated Output Power
E
ff
ic
ien
cy
, %
240/195VDC
240/266VDC
240/480VDC
208/195VDC
208/266VDC
208/480VDC
208 Efficiency: CEC 95.0%; Peak 95.7%
240 Efficiency: CEC 95.5%; Peak 96.0%
per P erformance Test Pro to co l fo r Evaluating Inverters Used in Grid-Co nnected P ho tovoltaic Systems (as ado pted by CEC)
4kW Efficiency vs Output Power
89
90
91
92
93
94
95
96
97
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
% of Rated Output Power
E
ff
ic
ien
cy
, %
240/195VDC
240/266VDC
240/480VDC
208/195VDC
208/266VDC
208/480VDC
208 Efficiency: CEC 95.0%; Peak 95.6%
240 Efficiency: CEC 95.0%; Peak 95.9%
per Perfo rmance Test P ro to co l for Evaluating Inverters Used in Grid-Connected Pho to vo ltaic Systems (as adopted by CEC)