2.0 INSTALLATION
Figure 7
Terminal Block Connections
Generator Wiring
Connect the generator auto-start wires to RY7 for the RUN/GLOWSTOP
functions and RY8 (if used) for the START circuit.
To connect the generator wires to the terminal block
Lift the appropriate lever for the relay contact.
Insert the wire (stripped back 1/4 inch) into the terminal block.
Snap the lever down to secure the wire.
Please refer to the generator section of the inverters operation manual
for additional information.
NOTE: Due to the various wiring schemes used by different
manufacturers, detailed wiring instructions can not be given in this
manual. Please refer to the generator manufacturers documentation
for wiring details.
CAUTION: DO NOT WIRE THE RELAYS DIRECTLY TO A HIGH-
AMPERAGE DEVICE, SUCH AS A STARTER MOTOR. THESE
RELAYS ARE DESIGNED TO INTERFACE WITH THE
GENERATORS AUTO-START CIRCUIT (LOW-CURRENT SIG-
NALS) ONLY. CONNECTION TO A HIGH-CURRENT DEVICE WILL
OPEN THE FUSE IN THE COMMON LINE AND Possibly DAMAGE
THE RELAY.
NOTE: All wiring described in this manual must be performed by a
qualified, licensed electrician and meet local and national codes,
such as NEC.
RELAY 7
Connections
RELAY 8
Connections
RELAY 11
Connections