3.0 OPERATION
46
©2000 Xantrex Technology Inc.
Front Panel Controls and Indicators
(continued)
LED Indicators
There are four LEDs on the inverters front panel, indicating inverter status, battery condition,
over temperature/overload conditions and charger status. These LEDs blink or change color
depending on the condition or function they are displaying.
Figure 42
LED Indicators
Inverter Mode LED - Green
The green Inverter Mode LED lights (solid) to indicate the inverter is running on batteries (full
wave operation). When the inverter is in search mode (no load applied) the LED flashes 2 to 3
times per second. During AC line operation, with AC passing directly through to the connected
load, the LED remains OFF.
Over Temp / Overload LED - Red / Green
(error condition)
The Over Temp / Overload LED is a dual color, dual function indicator. When the inverters
temperature is too high for safe operation, the LED lights (red) to indicate the Over Temp
condition. When the temperature returns to a safe level, the LED turns OFF. If the condition
persists, the inverter will shut down, cool and then restart.
Whenever the current draw exceeds a value programmed into the micro-controller, the LED
lights (green) to indicate the Overload condition. The LED can remain ON for up to one hour
(before inverter shutdown) if the condition is caused by a fault in the charger circuit. When the
fault condition clears, the LED turns OFF. If the condition is caused by backfeed (connecting the
AC line to the inverters output) the LED will remain ON for approximately 10 seconds before the
inverter shuts down.