background image

11

Controllers

Smart Pad

3

TO PM110

®

TO EM110

L+

L–

R–

R+

SPEAKER

OUTPUT

L+

L–

R–

R+

AMPLIFIER

INPUT

PM110

SMART PAD

3

PROGRAMMABLE MODULE

+12V

IR OUT

ST

A

TUS

GND

TM

®  SYLMAR, CA                        MADE IN U.S.A.

20-Conductor Ribbon Cable & Plug Ass'y (supplied with EM110)

PM110

(Rear)

EM110

(Rear)

Red Stripe

Red Stripe

Fig. 10  

3-Gang EM110 to PM110 Connections

selections on CD, Channel selection on SAT & VCR, etc., on
their respective banks.

3. The 

TNR

,

TNR

 buttons for the AM/FM Tuner can also serve as

Channel Up/Down for SAT & the VCR TV tuner.

4. Use the 2nd tier on the TUNER button for AM/FM selection,

if desired.

Programming a Three Gang
Configuration

1. When you have completed the assembly of the buttons and

the modules and have installed them into the PM110 &
EM110 as shown in 

Fig. 9

, connect them together with the

ribbon cable as shown in 

Fig. 10

.  Locate 

red stripe

 side of

cable as shown.

2. You can now program this configuration in the same manner as described in the procedures on pages

9 through 11.

3. When you have completed all programming, you can 

transfer

 this whole command set to any number

of additional keypads (identically configured), as needed, in multi-room installations.  Refer to the
"

Command Transfers

 (Cloning)" section.

BUTTON AND MODULE ASSEMBLY

The key module assemblies have been designed specifically so that they can be custom configured with
the desired button arrangements.  To assemble, disassemble, change and reassemble, as desired,
proceed as follows:

Assembly

Fig. 11  

Typical Key Module Assembly

Rubber

Actuators

Key Module

Shell

Rear

Tab

Cursor

Buttons

Retainer

Tabs

18-Pin

Connector

Key Module

PCB & Base

Retainer

Slots

Function

Keys

Bank

(Source)

Buttons

1. First, decide on the buttons you need and their locations (see

examples on pages 8,12 & 17).

2. Pick up the 

Key Module PCB & Base 

assembly and carefully

push each 

button

 onto the 

Rubber Actuators

 in the locations

you desire.  Refer to 

Fig. 11

.

(As received from the factory, the key module shell is separate
from the key module PCB & base assembly).

3. When the buttons are completely in place, pick up the 

Key

Module Shell

 and lower it over the 

Key Module PCB & Base

assembly.  (

Figs. 11 & 12

).

Key Module

Shell

Key Module

PCB & Base

Rear

Tab

Front

Tab

Assembled

Buttons

Fig. 12  

Assembly of Key Module Shell

4. Move the buttons slightly, as necessary, to align them so

that they pass through the button openings in the 

Key

Module Shell

.

5. Carefully press the 

Key Module Shell

 down until the 4

small 

Retainer Tabs

 (

Fig. 11

) on the 

Key Module PCB

& Base 

assembly

 

snap into the corresponding 

Retainer

Slots

 on the 

Key Module Shell

.

6. Mount the completed key module into the PM110 (or

LM110 or EM110).  Place the 

Front Tab

 on the module

under the 

Small Lip

 of the PM110. Align the 

18-pin plug

with the 

18-pin socket

 and carefully push into place.  See

Fig. 13

.

Содержание SMRTP3

Страница 1: ...markings are included with each key module Many specialized versions are also separately available from Xantech Pre labeled buttons do not require any tedious insertion of small icon key caps Up to 8...

Страница 2: ...have 12 buttons The last four have 11 buttons and include a cursor key cluster The module shells and buttons are available in white ivory and black An illustration and description of each follow KM1F...

Страница 3: ...system into which the Key Modules are docked They contain the electronics for programming memory except the EM110 and include flanges for J box mounting An illustration and description of each follow...

Страница 4: ...for the second Key Module 3 Now since this is a 2 gang configuration we need a PM110 Base Module into which we plug theKM1F and the KM4 Fig 1 shows the basic configuration Fig 1 Two Gang Configuratio...

Страница 5: ...d commands and the Switched AC Outlet on the AM FM receiver Refer to Fig 3 We ll begin by teaching commands to the 4 source bank buttons TO EM110 L L R R SPEAKER OUTPUT L L R R AMPLIFIER INPUT 12V IR...

Страница 6: ...d remote at the IR window and press it s play button 5 When the code is learned the PGM LED will flash again indicating it is ready to learn a command at another button 6 Press reverse scan button The...

Страница 7: ...owing equipment and system requirements 1 An AM FM receiver and 4 sources TUNER AM FM two CD changers and a cassette TAPE deck 2 When a source button is pressed it must turn the AM FM receiver ON alon...

Страница 8: ...tions in order for the source indicators and bank selections to operate 7 The keypad is now ready to be wired into the total system See Fig 6 Power may then be applied and we can proceed with the Prog...

Страница 9: ...de is learned the SEQ LED will flash then go steady when you release the key on the remote 14 Press CNCL two times to exit the programming tier mode You can now test these learned commands But first b...

Страница 10: ...changer an LD Laser Disc player a cassette TAPE deck a SAT Satellite receiver and a VCR 2 When a source button is pressed it must turn on the AM FM receiver and the associated source 3 The keypad mus...

Страница 11: ...ly so that they can be custom configured with the desired button arrangements To assemble disassemble change and reassemble as desired proceed as follows Assembly Fig 11 Typical Key Module Assembly Ru...

Страница 12: ...push hold tiering and sequence commands on any key Commands storable into 1 to 8 banks selectable by bank keys Editing of command sequences Intelligent Power Management inhibits first command in a seq...

Страница 13: ...rols for programming only It will not repeat commands through the network system 13 COM Port RS232 signal compatible port for uploading or downloading to from a computer or transferring programmed con...

Страница 14: ...e keypad defaults to bank 1 top left source button after each power up The unit is now ready for programming communications with a PC or cloning of programmed contents from one keypad to another Learn...

Страница 15: ...d you want in the sequence 4 When the command has been learned the SEQ and PGM LEDs begin flashing and continue to flash until you release the key on the remote 5 The SEQ LED will then turn on steady...

Страница 16: ...e button in a 2 step sequence This permits sources to be selected after zone turn on They would otherwise be blocked when zone turn on drives the STATUS line high Tiering The SmartPad3 has the ability...

Страница 17: ...he keypad and have pressed CNCL to leave the programming modes you may send them to the controlled equipment simply by pressing the key that relates to them It is recommended that you test each set of...

Страница 18: ...ED will come on steady 8 Input the IR command in the normal manner 9 When stored the PGM and SEQ LED will flash then go out You may now STEP to the next command NOTE You do not have to delete anything...

Страница 19: ...ystem STATUS Voltage 12VDC 12 VDC GND STATUS IR IN EMITTERS IR RCVR 789 44 CONNECTING BLOCK Fig 20 Network Connection Diagram Programming for the Speaker Relay The relay will respond to commands for M...

Страница 20: ...23 9 Test the IR commands by setting the rear switches on the RC68 to D8 the factory default Code Group setting for the SmartPad3 10 Pressing the 0 ON TOG IR command on the RC68 should cause the Relay...

Страница 21: ...le TOGGLE command for instance would work well under the MUTE button in a system such as that in Figs 5 6 To program Toggle only proceed as follows 19 Begin by following steps 1 through 7 20 At this p...

Страница 22: ...ressing D8 in the above process or by doing a CLR MEM Fig 15 Be aware that CLR MEM will erase all user programming Bank Tracking Programming Each Source bank key of the SmartPad3 can be programmed to...

Страница 23: ...e 90 from the RC68 into the TUNER bank of the 1 keypad To do this follow the previous procedure steps 1 through 8 Now pressing CD or TUNER on either keypad will result in them tracking together Comman...

Страница 24: ...y refer to Fig 31 To perform a Network Transfer proceed as follows 1 Connect up to 16 keypads onto a common IR bus network Refer to Fig 31 Be sure the system is powered up 2 If you have not already do...

Страница 25: ...witch to the PROTECT position on all keypads to prevent unintended alteration or erasure Cloning Transfer Time The time it takes to complete a cloning process depends on the amount of data required fo...

Страница 26: ...other wall mounted decorator style components A few things to keep in mind are as follows NETWORK RESTORE COM PORT B A9876 5 4 3 2 1 0 F E D C NETWORK ADDRESS WRITE PROTECT WRITE READ 1 3 4 LM110 1 1...

Страница 27: ...er does not output IR commands Corrupted data in the 2nd keypad may have prevented a proper data transfer a Press the CLR MEM button twice on the 2nd keypad b Repeat the Command Transfers Cloning proc...

Страница 28: ...signal output current 100 milliamps STATUS Terminal Power Management Turn on Voltage 5 to 30 volts DC 8mA 12V DC COM Port RS232 Signal Compatible Speaker Relay Stereo Speaker Pair Muting Contact Ratin...

Отзывы: