Xantech SMRTP3 Скачать руководство пользователя страница 3

3

Controllers

Smart Pad

3

The 

CM1N

 is similar to the CM1F except that it is set up for use with 6  numeric control buttons as well as

the 5 cursor keys.  

Numeric

 and 

cursor

 buttons are included.

The 

CM1F

 module includes 6  function control keys plus a cursor button cluster with Up, Down, Left, Right,

and Enter keys. The cursor keys can be used with sources that have menu driven on-screen displays.

Cursor

 keys and a selection of 

function

 buttons are included.

The 

CM4

 is similar to the CM1F except that it is set up for use with 4 source (bank) and 2 function keys as

well as the 5 cursor keys.  

Cursor

 keys and a selection of 

source

 and

 function

 buttons are included.

The 

CM6

 is similar to the CM1F except that it is set up for use with 6 source (bank) keys as well as the 5

cursor keys.  

Cursor

 keys and a selection of 

source

 buttons are included.

The Base Modules

There are three base modules in the 

SmartPad

3

 system into which the Key Modules are docked.  They

contain the electronics for programming & memory (except the EM110) and include flanges for J-box
mounting.  An illustration and description of each follow:

CM1N

CM4

CM6

CM1F

CLR MEM

RESTORE

NETWORK

PGM

TRNS

XFER

ERR

CNCL

FULL

DEL

EDIT

DELAY

SEQ

IR

STEP

C
O
M

B A 9 8 7 6

5

4

3

2

1

0

F

E

D

C

PROTECT

WRITE

NETWORK

ADDRESS

PM110

LM110

NETWORK

RESTORE

COM  PORT

B A 9 8 7 6

5

4

3

2

1

0

F

E

D

C

WRITE

NETWORK

ADDRESS

PROTECT

EM110

The PM110 dual gang 

Programmable Module

 is the base module for programming all of the commands

and functions required for each installation.  All programming, including sequences (macros), is done with
the PM110 (unless done with Dragon Drop-IR™).

The LM110 

Learning Module

 is intended for single gang applications and must receive its programming

from a PM110 or Dragon Drop IR™ system.  Programs are transferred from the PM110 or Dragon Drop IR
to the LM110 with a 2-step transfer command.

The EM110 is a single gang 

Expansion Module

. It has no memory and serves only to expand the number

of key functions for the PM110 in 3-gang configurations.

Содержание SMRTP3

Страница 1: ...markings are included with each key module Many specialized versions are also separately available from Xantech Pre labeled buttons do not require any tedious insertion of small icon key caps Up to 8...

Страница 2: ...have 12 buttons The last four have 11 buttons and include a cursor key cluster The module shells and buttons are available in white ivory and black An illustration and description of each follow KM1F...

Страница 3: ...system into which the Key Modules are docked They contain the electronics for programming memory except the EM110 and include flanges for J box mounting An illustration and description of each follow...

Страница 4: ...for the second Key Module 3 Now since this is a 2 gang configuration we need a PM110 Base Module into which we plug theKM1F and the KM4 Fig 1 shows the basic configuration Fig 1 Two Gang Configuratio...

Страница 5: ...d commands and the Switched AC Outlet on the AM FM receiver Refer to Fig 3 We ll begin by teaching commands to the 4 source bank buttons TO EM110 L L R R SPEAKER OUTPUT L L R R AMPLIFIER INPUT 12V IR...

Страница 6: ...d remote at the IR window and press it s play button 5 When the code is learned the PGM LED will flash again indicating it is ready to learn a command at another button 6 Press reverse scan button The...

Страница 7: ...owing equipment and system requirements 1 An AM FM receiver and 4 sources TUNER AM FM two CD changers and a cassette TAPE deck 2 When a source button is pressed it must turn the AM FM receiver ON alon...

Страница 8: ...tions in order for the source indicators and bank selections to operate 7 The keypad is now ready to be wired into the total system See Fig 6 Power may then be applied and we can proceed with the Prog...

Страница 9: ...de is learned the SEQ LED will flash then go steady when you release the key on the remote 14 Press CNCL two times to exit the programming tier mode You can now test these learned commands But first b...

Страница 10: ...changer an LD Laser Disc player a cassette TAPE deck a SAT Satellite receiver and a VCR 2 When a source button is pressed it must turn on the AM FM receiver and the associated source 3 The keypad mus...

Страница 11: ...ly so that they can be custom configured with the desired button arrangements To assemble disassemble change and reassemble as desired proceed as follows Assembly Fig 11 Typical Key Module Assembly Ru...

Страница 12: ...push hold tiering and sequence commands on any key Commands storable into 1 to 8 banks selectable by bank keys Editing of command sequences Intelligent Power Management inhibits first command in a seq...

Страница 13: ...rols for programming only It will not repeat commands through the network system 13 COM Port RS232 signal compatible port for uploading or downloading to from a computer or transferring programmed con...

Страница 14: ...e keypad defaults to bank 1 top left source button after each power up The unit is now ready for programming communications with a PC or cloning of programmed contents from one keypad to another Learn...

Страница 15: ...d you want in the sequence 4 When the command has been learned the SEQ and PGM LEDs begin flashing and continue to flash until you release the key on the remote 5 The SEQ LED will then turn on steady...

Страница 16: ...e button in a 2 step sequence This permits sources to be selected after zone turn on They would otherwise be blocked when zone turn on drives the STATUS line high Tiering The SmartPad3 has the ability...

Страница 17: ...he keypad and have pressed CNCL to leave the programming modes you may send them to the controlled equipment simply by pressing the key that relates to them It is recommended that you test each set of...

Страница 18: ...ED will come on steady 8 Input the IR command in the normal manner 9 When stored the PGM and SEQ LED will flash then go out You may now STEP to the next command NOTE You do not have to delete anything...

Страница 19: ...ystem STATUS Voltage 12VDC 12 VDC GND STATUS IR IN EMITTERS IR RCVR 789 44 CONNECTING BLOCK Fig 20 Network Connection Diagram Programming for the Speaker Relay The relay will respond to commands for M...

Страница 20: ...23 9 Test the IR commands by setting the rear switches on the RC68 to D8 the factory default Code Group setting for the SmartPad3 10 Pressing the 0 ON TOG IR command on the RC68 should cause the Relay...

Страница 21: ...le TOGGLE command for instance would work well under the MUTE button in a system such as that in Figs 5 6 To program Toggle only proceed as follows 19 Begin by following steps 1 through 7 20 At this p...

Страница 22: ...ressing D8 in the above process or by doing a CLR MEM Fig 15 Be aware that CLR MEM will erase all user programming Bank Tracking Programming Each Source bank key of the SmartPad3 can be programmed to...

Страница 23: ...e 90 from the RC68 into the TUNER bank of the 1 keypad To do this follow the previous procedure steps 1 through 8 Now pressing CD or TUNER on either keypad will result in them tracking together Comman...

Страница 24: ...y refer to Fig 31 To perform a Network Transfer proceed as follows 1 Connect up to 16 keypads onto a common IR bus network Refer to Fig 31 Be sure the system is powered up 2 If you have not already do...

Страница 25: ...witch to the PROTECT position on all keypads to prevent unintended alteration or erasure Cloning Transfer Time The time it takes to complete a cloning process depends on the amount of data required fo...

Страница 26: ...other wall mounted decorator style components A few things to keep in mind are as follows NETWORK RESTORE COM PORT B A9876 5 4 3 2 1 0 F E D C NETWORK ADDRESS WRITE PROTECT WRITE READ 1 3 4 LM110 1 1...

Страница 27: ...er does not output IR commands Corrupted data in the 2nd keypad may have prevented a proper data transfer a Press the CLR MEM button twice on the 2nd keypad b Repeat the Command Transfers Cloning proc...

Страница 28: ...signal output current 100 milliamps STATUS Terminal Power Management Turn on Voltage 5 to 30 volts DC 8mA 12V DC COM Port RS232 Signal Compatible Speaker Relay Stereo Speaker Pair Muting Contact Ratin...

Отзывы: