background image

 

 

Crestron GLPPA-KP 

Keypad for GLPP 

Installation Guide 

Crestron Electronics, Inc.

 

Installation Guide - DOC. 7211B

15 Volvo Drive   Rockleigh, NJ 07647 

(2031031)

Tel: 888.CRESTRON 

08.13

Fax: 201.767.7576  

Specifications subject to 

www.crestron.com 

change without notice.

DESCRIPTION 

•  T

o be installed and/or used in accordance with appropriate electrical codes and regulations. 

• 

If you are unsure about any part of these instructions, consult a qualified electrician. 

WARNING: 

To avoid fire, shock, or death; turn off power at circuit breaker or fuse and test that power is off before 

wiring!

NOTES: 

Observe the following: 

The GLPPA-KP is an in-wall keypad for Crestron Green Light

®

 Power Pack (GLPP) 

systems, used to set and recall presets and turn on and off all loads connected to a 

GLPP. Installation is made easy thanks to a 2-wire, low-voltage bus, which connects the 

GLPPA-KP and GLPP main unit. Available in black, white, and almond, the GLPPA-KP 

fits almost any décor. Up to three GLPPA-KPs can be connected to a single GLPP 

system for multipoint control in a room.

Flexible Configuration

Two sets of button configurations accompany every GLPPA-KP: a rocker for turning 

on/off and dimming and a set of four pre-labeled buttons—

ALL ON

ALL OFF

SCENE 1

, and 

SCENE 2

. Scenes can be adjusted by any user directly right from the 

keypad.

Easy Installation

Two flying leads connect the GLPPA-KP to the GLPP system via a non-polarized 

low-voltage bus. Use a choice of new or existing high-voltage (Class 1) or low-voltage 

(Class 2) wiring for quick installation. 

Specifications

Specifications for the GLPPA-KP are listed in the following table.

 

Further Inquiries

To locate specific information or resolve questions after reviewing this guide, contact Crestron's True 

Blue Support at 1-888-CRESTRON [1-888-273-7876] or, for assistance within a particular geographic 

region, refer to the listing of Crestron world wide offices at www.crestron.com/offices.

To post a question about Crestron products, log onto Crestron's Online Help at 

www.crestron.com/onlinehelp. First-time users must establish a user account to fully benefit from all 

available features.

Future Updates

As Crestron improves functions, adds new features, and extends the capabilities of the GLPPA-KP units, 

additional information may be made available as manual updates. These updates are solely electronic 

and serve as intermediary supplements prior to the release of a complete technical documentation 

revision.
Check the Crestron Web site periodically for manual update availability and its relevance. Updates are 

identified as an “Addendum” in the Download column.

This product is Listed to applicable 

UL Standards and requirements by 

Underwriters Laboratories Inc.

SPECIFICATION

DETAILS

GLPPA-KP Specifications

Environmental

     Temperature 

32º F to 113º F (0º C to 45º C)

     Humidity 

10% to 90% RH (non-condensing)

Power Requirements 

1 watt (0.05 amps @ 24 volts dc) supplied by GLPP 

over proprietary 2-wire bus

Dimensions

     Height 

4 1/8 in (105 mm)

     Width 

1 3/4 in (45 mm)

     Depth 

1 13/16 in (46 mm)

Weight 

4 oz (50 g)

Enclosure 

Injection molded plastic, one gang mountable in a 

standard electrical box, requires decorator style 

faceplate (not supplied)

GLPPA-KP Dimensions

1 3/4 in

(45 mm)

1 13/16 in

(46 mm)

4 1/8 in

(105 mm)

INSTALLATION

Wiring

1.  Using new or pre-existing wiring, connect the two non-polarized white wires with black 

stripes from the GLPP-DIM or GLPP-SW to the two wires on the keypad.

2.  If a second or third GLPPA-KP is being used in the room, wire them in parallel.

Wiring the GLPPA-KP

GLPP

Primary GLPPA-KP

Secondary GLPPA-KP 

(Optional)

White/Black
White/Black

Отзывы: