37
Remove the Peristaltic Pump Housing
Top Cover, then use a 2.0 screwdriver to
remove the five (5) screws securing the
Pump Controller Board and remove the
board for replacement.
The screws using M2.5*6*4.5 Hexagon
socket combination screw here.
1.
Drain all liquid and residues from the liquid tube, then use a 2.5 screwdriver to remove the
six (6) screws securing the Peristaltic Pump Housing.
The screws using M3*12*6 Hexagon socket combination screw here.
2.
Use a 2.0 screwdriver to remove the nine (9) screws securing the Peristaltic Pump Housing
Top Cover, then disconnect the connectors of the Peristaltic Pump and the connector of the
Searchlight.
Pump Controller Board
🔧
Disassemble:
P20/P30 2019 Pump Controller Board
*1
SKU-05-001-00556
M3*12*6 Hexagon socket combination screw
*6
SKU-02-004-00225
M2.5*8*4.5 Hexagon socket combination screw
*9
SKU-02-004-00429
M2.5*6*4.5 Hexagon socket combination screw
*5
SKU-02-004-00428
💡
What do we need in this section: