Setting 

Description 

Default 

Enable 

Turn on logging for this channel 

On 

Alias 

Freely selectable channel name 

trigger_button or 
wake_line 

Bus ID 

Additional ID for subsequent evaluation 

 

Prevent Sleep 
Mode 

Datalogger will not go into sleep mode as 
long as there is activity on this channel 

On 

Send Event 

Generate an additional event message either 
at the falling or at the rising edge 
Values: Falling edge, No event, Rising edge 

Rising edge 

Wake 

Datalogger wakes up from sleep mode as 
soon as there is activity on this channel 

On 

Debounce 
time 

Bridging time (in µs) to prevent undesired 
multiple events when a trigger is raised 

1000 

Action 

(1)

 

Start logging 

On 

Action 

(2)

 

Stop logging 
Long press is required (at least 3 s) 

On 

Action 

(3)

 

Create snapshot 

Off 

Action 

(4)

 

Eject USB device 
Long press is required (at least 3 s) 

Off 

Action 

(5)

 

The video stream currently stored in the 
circular buffer is saved permanently 

Off 

Action 

(6)

 

Create screenshot 

Off 

Action 

(7)

 

Start video stream 

Off 

Action 

(8)

 

Stop video stream 

Off 

Action 

(9)

 

Send CAN trigger response 1 

Off 

Action 

(10)

 

Send CAN trigger response 2 

Off 

 

 

Содержание XORAYA N4000

Страница 1: ...User Manual XORAYA N4000 XORAYA N4000 Version 1 1 6...

Страница 2: ...th permission of X2E GmbH Offenders shall be liable to pay compensation and may be subject to prosecution All product names and trademarks used in this manual are the property of their respective owne...

Страница 3: ...nections and controls 19 4 Commissioning 26 4 1 Unpacking 26 4 2 Selecting an installation location 26 4 3 Installing the datalogger 26 4 4 Installing the XORAYASuite 27 4 5 Connecting the datalogger...

Страница 4: ...F CONTENTS 4 6 1 Safety measures 171 6 2 Cleaning 172 6 3 Repair 173 7 Storage transport and disposal 174 7 1 Storage 174 7 2 Transport 174 7 3 Disposal 174 8 Appendix 176 8 1 Technical data 176 8 2 S...

Страница 5: ...tion for safe proper and efficient operation of the datalogger Following this user manual strictly helps in avoiding dangers reduces repair costs and downtime while increasing the reliability and serv...

Страница 6: ...n change certain properties and functions via the included software so that the datalogger behaves differently than described herein Users may revert to factory defaults at any time by pressing the de...

Страница 7: ...This symbol indicates license information License information contains either general information about licenses for the datalogger or indicates whether a license is required for a particular function...

Страница 8: ...nings are separated from the surrounding text by lines set above and below SIGNAL WORD Danger types and sources Explanation and consequence of danger Actions to prevent danger 1 5 X2E Wiki The X2E Wik...

Страница 9: ...ng the GUI of the XORAYASuite The datalogger is intended for use only by trained personnel The datalogger must not be used in residential or living areas Its use is strictly limited to industrial envi...

Страница 10: ...tion or repair Check the connecting cable regularly for defects to prevent damage to the power source Always install the datalogger in de energized status WARNING Defects influencing the environment T...

Страница 11: ...ed temperature range Never operate the datalogger near heat sources Please ensure adequate air circulation for operation Do not cover the datalogger with other objects CAUTION Device damage due to sho...

Страница 12: ...of the datalogger Never disconnect the datalogger from the power supply while in operation Ensure proper connector seating and tighten the screws if possible Only shut down the datalogger through the...

Страница 13: ...ts shall apply The datalogger is continuously developed The development process relies on the cooperation between the user and X2E GmbH 2 6 Warranty The warranty period is 12 months Device batteries w...

Страница 14: ...ss B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates...

Страница 15: ...ommercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio com...

Страница 16: ...tal In eSATA XORAYA N4000 and XORAYA N4000 are based on the Xilinx Zynq UltraScale MPSoC The built in supercapacitor unit is able to bridge power fluctuations and to shut the datalogger down safely in...

Страница 17: ...0200 XORAYA Datalogger Second block Product variant 0700 XORAYA N4000 0720 XORAYA N4000 Third block Hardware revision Input Maximum current consumption at given standard input voltage S N Unique seria...

Страница 18: ...manual Cable set depending on the interface configuration The following accessories are optionally available Power supply cable with AC adapter recommended XORAYA External Storage Unit Additional cabl...

Страница 19: ...s The back side of the datalogger contains the log interfaces Front side N4000 N4000 A Status LEDs of custom log interfaces H Default button B Status LEDs of built in log interfaces I Service interfac...

Страница 20: ...ing Label the USB flash drive XORAYALOG and create the folder usb_queue there Check Record on USB stick in the Hard Disk category of the system settings Hard Disk Start data recording in HDD mode HDD...

Страница 21: ...ate or recovery mode Displays different error codes by flashing HDD Flashes when accessing the internal storage medium USB Flashes when accessing a connected USB flash drive ext HDD Lights up when XOR...

Страница 22: ...nterface can be used for data recording or as a faster alternative to the 1 Gbit host interfaces E A plugged in SFP module is required X2E recommends the module FTLX8573D3BTL from Finisar Default butt...

Страница 23: ...s button when the device is connected to a PC and the Connect LED is lit In this case you can turn off the datalogger via the Logger menu of the XORAYASuite Here you may choose between two options i e...

Страница 24: ...P Built in log interfaces O Custom log interfaces Switch and pin assignments The switch Switch assignments and pin assignments Pin assignments of the log interfaces can be found in the appendix Add on...

Страница 25: ...erface configuration Main overview for all interfaces Main overview for all channels of one interface type Settings for the corresponding interface channel Built in log interfaces P The built in inter...

Страница 26: ...cted component upon prompt notification Keep original packaging Keep the original packaging and packing materials for later storage or further transport 4 2 Selecting an installation location The data...

Страница 27: ...Bit or 64 Bit Microsoft Windows 8 32 Bit or 64 Bit Microsoft Windows 10 32 Bit or 64 Bit Hardware requirements Processor speed at least 1 GHz RAM at least 2 GB Storage space approx 120 MB available So...

Страница 28: ...s Observe pin assignments Please note the port pin assignments when connecting the datalogger with the measuring environment Wrong pin assignments lead to measurement errors Please note the following...

Страница 29: ...rrect power supply Using an incorrect power supply can lead to abnormal behavior or destruction of the datalogger Use only the supplied power cable Please ensure correct polarity upon connection Make...

Страница 30: ...the red plug to the power supply The datalogger is securely connected to the measuring environment Once the supply voltage is established the datalogger turns on and displays its operational status v...

Страница 31: ...om sleep mode as follows Pressing the power button L Switching the power supply off and on Signal change from 0 V to 12 V at the trigger or wake input M Pressing the trigger wake button K Activity on...

Страница 32: ...Manage datalogger group Configuration Customize the datalogger behavior Online Logging Start and stop logging Hdd Download Download measurements from the datalogger storage medium Viewer Evaluate meas...

Страница 33: ...ves the current interface configuration under a different name The subitem System settings and signals saves everything except the interface configuration Open Opens an info file DLI and the associate...

Страница 34: ...atalogger Customer default configuration Create Stores the current permanent configuration profile active in the customer default profile Customer default configuration Load Loads the customer default...

Страница 35: ...ze columns Adjusts the width of the columns in the Hdd Download tool to ensure all are visible simultaneously 1 Comment 22 Type spread Determines which tabs are shown in the Hdd Download tool Legend D...

Страница 36: ...the most Their descriptions can be found in the corresponding sections of this user manual 5 3 Status bar The status bar on the bottom of the window provides information about the connected datalogger...

Страница 37: ...red XORAYASuite tool Starting Click Display available loggers 1 to start scanning for dataloggers Select the desired datalogger using the assigned name Click Establish connection to logger 2 or In the...

Страница 38: ...ggers 1 in the Configuration tool 5 4 2 Disconnecting the datalogger 2 Release connection to logger 5 Display settings 3 Start Hdd logging Click Release connection to logger 2 or In the Logger menu cl...

Страница 39: ...y 6 Remove device from favorite list Save frequently used dataloggers in the favorites list Favorites are displayed first in the list of available dataloggers and are marked with the star symbol Add d...

Страница 40: ...Connect to the desired datalogger Connecting the datalogger The configuration can be performed WARNING Defects influencing the environment The incorrect datalogger configuration can lead to the tempo...

Страница 41: ...o access the sub items The current configuration of the selected sub item is displayed on the right side of the window This is where you can perform any changes required and optionally save them as a...

Страница 42: ...changed configuration permanently The configuration is saved permanently Delayed change update For certain settings such as Name and IP Address changes are not applied immediately but only after a da...

Страница 43: ...red on the datalogger These properties fall under various categories Main Settings Network Hard Disk Snapshot Versions Profile Select the category Click the root element of System Settings to display...

Страница 44: ...d property for the system time Automatically Switch Off Time period after which the datalogger shuts down provided there is no connection to the XORAYASuite there is no activity on any interface for w...

Страница 45: ...rk The sub categories are assigned to the following interfaces Connections and controls LAN Host eth0 LAN host interfaces E LAN Host eth1 10 Gbit Ethernet interface G 1 Overall view 4 Connection matri...

Страница 46: ...255 255 0 fixed IP Address Datalogger with static IP address Off max transmit unit mtu maximum packet size on the network layer in Bytes 1500 Provided the check box is selected the datalogger is only...

Страница 47: ...to IP addresses Type them in manually or double click in a row of the table that contains the addresses of the PCs in the network Red exclamation marks flag PCs outside the IP range Special care in ne...

Страница 48: ...ate internal storage medium 4 Remove ESU safely Only with connected XORAYA ESU These settings and displays refer to the currently active storage medium represented by the blue background color If a XO...

Страница 49: ...f on the internal or external storage medium Off Disabled Loop Circular buffer which contains the most recent minutes of the recording Linear Ongoing Off Compression Compression reduces the data volum...

Страница 50: ...Measurement data are processed as queues on the log interfaces In addition to the default queue for packet data the datalogger is able to use the faster stream queue where Ethernet data are saved dir...

Страница 51: ...eue in ms 0 Trigger Post time Stream queue Trailing time of the snapshot for the stream queue in ms 0 Log mode Stream queue Snapshot recording mode for the stream queue Linear Ongoing Loop In a loop t...

Страница 52: ...ult configuration customer default a customer default configuration 1 Activate password protection Create customer default profile Enter customer default in the text box and click Create or In the Log...

Страница 53: ...protected With enabled password protection you can still temporarily save settings and create profiles without needing to enter the password 1 Unlock password protection Unlock password protection for...

Страница 54: ...d for downloading later 1 Upload client settings onto the logger 2 Delete client settings from the logger Save settings on the datalogger Specify the export settings Export settings Specify the output...

Страница 55: ...N4000 XORAYA N4000 XORAYASUITE 55 System Settings DLN Set up a Distributed Logging Network consisting of data sink master and one or multiple probes For further information see the quick manual for th...

Страница 56: ...0 XORAYASUITE 56 System Settings Versions All properties in this category are immutable and purely informative Among other things this displays version numbers for various datalogger components as wel...

Страница 57: ...Filter Trigger Routing Other Advanced Interface or channel selection Click the root element Interfaces to display the main settings of all interfaces or Click an interface to display the main settings...

Страница 58: ...XORAYASUITE 58 Interfaces Double click a row in the table to jump directly to the corresponding interface or to the corresponding channel Reducing power consumption To reduce the datalogger power cons...

Страница 59: ...ble By default the FD specific settings are missing on the remaining channels CANFD_4PLUS_ For each of these licenses the number of CAN FD capable channels is increased by 4 Check in category Versions...

Страница 60: ...gger will not go into sleep mode as long as there is activity on this channel On Wake Datalogger wakes up from sleep mode as soon as there is activity on this channel On Acknowledge Send Acknowledgmen...

Страница 61: ...USER MANUAL XORAYA N4000 XORAYA N4000 XORAYASUITE 61 CAN Trigger 1 Number of bytes for the trigger 3 Number of bytes for the response 2 8 byte blocks of the trigger 4 Byte values of the response...

Страница 62: ...message Under Id specify the ID of the CAN message that raises a trigger Changing the numbering system Select the check boxes Extended Frame Can FD and Bit Rate Switch as desired Specify the Number o...

Страница 63: ...ger Select the check boxes Extended Frame Can FD and Bit Rate Switch as desired Specify the Number of bytes for the response 3 Specify the Byte values of the response 4 Repeat as necessary to configur...

Страница 64: ...ble Click Add routing 1 Under Source interface choose the receiving CAN channel Under Source msg ID specify the ID of the source message Changing the numbering system Select the check box Ext ID for a...

Страница 65: ...e CAN messages contain signals which hold the specific values General system statistics are for example RAM queue fill level CPU load Storage medium usage Interface statistics Transfer speed in kB s M...

Страница 66: ...e rest of the ID in orange is reserved and is automatically adjusted for each interface channel by the software Click the DBC button to open the generated messages and signals as a DBC file in a text...

Страница 67: ...A B A Use Busspec Load configuration template provided by the vehicle manufacturer Off Prevent Sleep Mode Datalogger will not go into sleep mode as long as there is activity on this channel On Wake Da...

Страница 68: ...Additional ID for subsequent evaluation Baudrate Transfer rate in bit s Values 20000 19200 9600 4800 2400 19200 Use Busspec Load configuration template provided by the vehicle manufacturer Off Preven...

Страница 69: ...N message Under Id specify the ID of the LIN message that raises a trigger Changing the numbering system Specify the payload bytes from 1 to 8 Set bits Repeat as necessary for up to a total of five tr...

Страница 70: ...USER MANUAL XORAYA N4000 XORAYA N4000 XORAYASUITE 70 RS 232...

Страница 71: ...s Number of data bits of a data block Values 5 bit 6 bit 7 bit 8 bit 8 bit Parity Parity check for error detection Values None Odd Even None Stopbits Number of stop bits that mark the end of a data bl...

Страница 72: ...Turn on logging for this channel On Alias Freely selectable channel name ethernet Bus ID Additional ID for subsequent evaluation Use Busspec Load configuration template provided by the vehicle manufac...

Страница 73: ...r MAC address Queue dispatching filter EtherType and VLAN Configure pre filters Click Add pre filter 1 Choose the Filter type only MAC is available at the current development stage Under Direction cho...

Страница 74: ...packet data If the Ethernet frame contains no or only one VLAN tag the filter conditions for the non existing fields are ignored Via Load presets you can configure filter conditions in such way that e...

Страница 75: ...N4000 XORAYA N4000 XORAYASUITE 75 Ethernet protocols In this configuration section you can add update and delete GNLog and DLT channels Both protocols are recorded via the LAN host ports or the Broad...

Страница 76: ...urer Off Prevent Sleep Mode Datalogger will not go into sleep mode as long as there is activity on this channel On Debug level Detail level of the debug information GNLog 0 to 3 max DLT 0 None to 6 Ve...

Страница 77: ...nnect another LAN host port E to the PC Control video recordings Create one or multiple signal based triggers of the VIDEO interface or Activate one or multiple trigger actions of the button interface...

Страница 78: ...s the sample configuration of a Basler camera Prevent Sleep Mode Datalogger will not go into sleep mode as long as there is activity on this channel On VIDEO Trigger 1 Add trigger 4 Delete trigger 2 T...

Страница 79: ...click Add trigger 1 Select the desired Trigger type 2 Create a single condition or multiple combined conditions for this trigger Create trigger conditions If required repeat the above steps for furth...

Страница 80: ...00 XORAYA N4000 XORAYASUITE 80 DiagCCP DiagCCP Settings 1 Clear all settings 5 Open selection file 2 Edit CAN interface channel 6 Settings 3 Open A2L file 7 Traffic light for the bus load 4 Traffic li...

Страница 81: ...sleep mode as long as there is activity on this channel Off Source Physical CAN channel to be used Can_1 can1 A2L file Description file which is suitable for the ECU and is loaded to configure the CC...

Страница 82: ...K button Levels of the Traffic light for the EPK check 4 green check successful yellow check not possible red check not successful Signal configuration Click Open selection file 5 and select a suitabl...

Страница 83: ...row for the event channel column or Highlight one or multiple rows and right click to activate these signals simultaneously for one event channel Select signals for the polling measurement mode Click...

Страница 84: ...save it optionally encrypted on the datalogger Other Status of the signal definition file 10 displays the current state of the file and changes its state by clicking not generated saved on datalogger...

Страница 85: ...rigger conditions the CCP recording provided it is activated starts and stops automatically at the beginning or ending of the data recording in online mode or HDD mode Configure triggers On the header...

Страница 86: ...ion file as a reduced A2L file and save it optionally encrypted on the datalogger Create and encrypt the signal definition file by selecting the check boxes under MDF Export of signals Add additional...

Страница 87: ...the definition of a seed and key function for the encrypted communication with the ECU Create and test the seed and key function Click Add basic structure of the function 1 Insert the algorithm that...

Страница 88: ...TE 88 DiagXCP DiagXCP Settings 1 Clear all settings 5 Open selection file 2 Edit interface channel 6 Settings 3 Open A2L file 7 Traffic light for the bus load 4 Traffic light for the EPK check 8 Engin...

Страница 89: ...Off Alias Freely selectable channel name xcp Bus ID Additional ID for subsequent evaluation Prevent Sleep Mode Datalogger will not go into sleep mode as long as there is activity on this channel Off...

Страница 90: ...der Settings 6 is activated Alias is also changed If the A2L contains multiple transport layer descriptions select the layer from the appearing window You can change this selection afterwards via the...

Страница 91: ...sult evaluation is displayed via the Traffic light for the bus load 7 If angle synchronous RPM dependent event channels are used select the Engine RPM 8 which influences the bus load calculation Confi...

Страница 92: ...the signal row for the event channel column or Highlight one or multiple rows and right click to activate these signals simultaneously for one event channel Select signals for the polling measurement...

Страница 93: ...alogger Other Status of the signal definition file 10 displays the current state of the file and changes its state by clicking not generated saved on datalogger saved encrypted on datalogger not saved...

Страница 94: ...rigger conditions the XCP recording provided it is activated starts and stops automatically at the beginning or ending of the data recording in online mode or HDD mode Configure triggers On the header...

Страница 95: ...ion file as a reduced A2L file and save it optionally encrypted on the datalogger Create and encrypt the signal definition file by selecting the check boxes under MDF Export of signals Add additional...

Страница 96: ...n 2 Input data This category consists of the following elements Overview of the configured event channels Timeout values changeable FlexRay buffer configuration partly changeable Mapping of the FlexRa...

Страница 97: ...ion Click Add basic structure of the function 1 Insert the algorithm that corresponds with the ECU Define the Input data 2 to test the function Click Execute function 3 The XORAYASuite calculates the...

Страница 98: ...iggers Snapshots the Button interface Event Settings Setting Description Default Enable Turn on logging for this channel On Alias Freely selectable channel name event Bus ID Additional ID for subseque...

Страница 99: ...u create trigger conditions that write custom event messages Configure triggers Click Add trigger 1 Select the desired Trigger type 2 Create a single condition or multiple combined conditions for this...

Страница 100: ...ions are triggered by the following trigger types Each trigger type is assigned a channel of the button interface as follows Connections and controls trigger_button Pressing the trigger button K wake_...

Страница 101: ...Rising edge Rising edge Wake Datalogger wakes up from sleep mode as soon as there is activity on this channel On Debounce time Bridging time in s to prevent undesired multiple events when a trigger i...

Страница 102: ...assigned names for easier handling Settings 1 Add signal manually 4 Refresh signals 2 Edit signal 5 Configured signals 3 Delete signal 6 Signal selection Select the desired signals from 6 to add them...

Страница 103: ...ory Versions of system settings to verify which licenses are activated for your datalogger Versions Add signal processing Click Add signal processing 2 Select the desired signal processing type The fo...

Страница 104: ...Settings Specify the Interval Click Save signal processing 1 The log signal processing is stored on the datalogger Interval of the log signal processing If you specify an interval the last measured va...

Страница 105: ...e out of five text boxes i e Number of classes Begin End Width and Span width you would like to specify or Select Automatic to create classes of constant width uniformly over the entire value range Co...

Страница 106: ...l 1 2 Cancel signal processing 4 Signal 2 The compound signal processing corresponds to a combined count signal processing for two signals and is processed by the XORAYASuite as a two dimensional matr...

Страница 107: ...dit signal processing 2 Delete signal processing Edit signal processing Select the signal processing in the list 1 Click Edit signal processing 3 or Right click the signal processing and then click Ed...

Страница 108: ...Logging Shutdown Logger Shut down logger without wake up Create Snapshot Snapshot Add trigger On the header of the desired trigger action click Add trigger 1 Select the desired Trigger type 2 Create...

Страница 109: ...e system configuration or one or all interfaces to their factory defaults or Press the default button D for at least 3 seconds to reset all datalogger settings Connections and controls The datalogger...

Страница 110: ...his case as the datalogger is fully autonomous in this mode HDD logging may still be started and stopped from the PC Simultaneous recording modes Both modes can be operated in parallel but separately...

Страница 111: ...rmat Output formats Acoustic warning or executing a script if a bus error is detected Buses to be recorded Color assignments for the interfaces Signal description Signal description settings Load conf...

Страница 112: ...ic 2 Stop online logging 10 Trigger acoustic signal to identify datalogger 3 Start Hdd logging 5 Set Trigger for later evaluation Online logging information is distributed over several tabs The follow...

Страница 113: ...properties Signals Monitoring of defined signals Signal selection Context menu Show or hide columns Hide selected signals Save load and delete signal lists Send Send user defined CAN RS 232 or Etherne...

Страница 114: ...n additional column Timediff is displayed when you set the Timemasters on a particular record This column contains the time difference of each record to the Timemaster Represent data in graphical form...

Страница 115: ...host interface C Connections and controls Optionally Connect a XORAYA ESU to the corresponding interface F Turn on the datalogger Start the HDD recording by pressing the trigger button K on the datal...

Страница 116: ...checked Hard Disk The session size exceeds the maximum size specified In this case the current session is closed and a new session for the current measurement starts Sessions are closed under the fol...

Страница 117: ...DLI serves as link This file contains information about the included log interfaces and references to the corresponding binary files File Format Meaning name dli ASCII Master file Contains information...

Страница 118: ...t the Hdd Download tool of the XORAYASuite Starting Connect to the desired datalogger Connecting the datalogger or Connect to a USB flash drive that contains recorded measurements or Connect to a dire...

Страница 119: ...s for example enable disable time groups or eject the USB flash drive automatically after disconnecting Color assignments for the interfaces Manage logger favorites Favorites Change temporary download...

Страница 120: ...download Edit menu Select all or Select none Sessions and Measurements tabs Calendar tab Time range tab Sessions Measurements You can show and hide the Sessions tab in the settings Select the check b...

Страница 121: ...time unit Click the single arrows d to jump one day or one week forward or backward Click the double arrows e to jump three days or three weeks forward or backward Click the graphical representation...

Страница 122: ...the end date c Use the arrows d optionally to apply the start date or to jump one day forward or backward Specify the end time e Click Apply f Limit the time range further by clicking and dragging ins...

Страница 123: ...logger Download log data Click Start download 3 or In the Download menu click Start The selected sessions or measurements are transmitted to the PC 3 Stop download from logger 7 Show download statisti...

Страница 124: ...ows display and analysis of records No datalogger connection is necessary to do this Start the Viewer tool of the XORAYASuite Starting The subsequent view is divided into four panels which can be resi...

Страница 125: ...n the File menu click Open and select the DLI file or Drag and drop the DLI file from the Windows Explorer into the Data panel Display recently opened measurements Click the arrow behind Open measurem...

Страница 126: ...t time format with date 100 nanoseconds or standard Show or hide columns Draw record signal in the Graphic tab of the Graphical output panel Graphic Timemaster An additional column Timediff is display...

Страница 127: ...specify whether scrolling is by row numbers or time Right click 1 to specify how many rows or how much time is scrolled per click on the double arrow buttons 2 Left click the single arrow buttons 3 t...

Страница 128: ...n This panel displays information about active measurement and search results Tabs Info Detail Search Trace Signals Comment Info This tab displays general information about all records for the open me...

Страница 129: ...Data values 2 Raw data 4 Raw data values Right click anywhere on the white or green background part of the user interface to select whether the underlying raw data 2 is also displayed alongside the da...

Страница 130: ...can be found in the following panels and tabs Information panel Signals tab Search filter and export panel Browse tab Search filter and export panel Find tab 1 Search condition 4 Go to next search res...

Страница 131: ...l 4 Find previous 12 Manage signal lists 5 Search box 13 Show signal details 6 Find next 14 Signals overview 7 Draw selected signals 15 Signal details 8 Previous Add signals to signals overview 14 Cli...

Страница 132: ...signals by using the Shift key or the Ctrl key Click Draw selected signals 7 to display the graphical representation in the Graphic tab Graphic Search message in open log data In the signals overview...

Страница 133: ...al list Click Add new signal list 16 Add signal to signal list Select the signal list 15 Select the signal in the signals overview 14 Click Add signal to list 17 Delete signal from signal list Select...

Страница 134: ...to the corresponding records in the Data panel In addition you can manage the bookmarks list 1 Previous 11 Search message by payload 2 Next 12 Search message by Interface ID and payload 3 All since cu...

Страница 135: ...e 12 To go to the next record that meets the desired search condition Select search criteria from the tabs 7 to 12 or Select the corresponding criterion from the drop down list 6 Specify the search co...

Страница 136: ...right click it in the Data panel and select the appropriate option Use the Browse tab to navigate between bookmarks or to delete them Event This tab displays all events generated by the user or by the...

Страница 137: ...expression Select the Field 1 that you would like to add to your search Select the Relation 2 between field and value Specify the Value 3 Depending on the field this is either presented as a text box...

Страница 138: ...list Search Cancel search Click Cancel 9 Interface Use this tab to filter the displayed records in the Data panel 1 Start 5 Select FlexRay IDs 2 Cancel 6 Interfaces 3 Filter region 7 Interface channe...

Страница 139: ...filter Add the desired filter Click Start 1 Records in the Data panel are filtered Cancel filter Click Cancel 2 Export Use this tab to export the records to various output formats 1 Export settings 3...

Страница 140: ...triggers sec Period before and after raised triggers Pre post triggers If this option is selected you can double click to change the time period before and after a trigger is raised Default values ar...

Страница 141: ...Graphic Video Overview This tab displays the timeline of the opened measurement Icons represent events bookmarks and search results You can also specify a Fine zone to filter the records to display an...

Страница 142: ...right click a record of the interface channel that you would like to see in graphical format Data Point to Draw signal Select the desired value The time curve of the value is displayed graphically Gr...

Страница 143: ...logger Start the Statistic tool of the XORAYASuite Starting Connect to the desired datalogger Connecting the datalogger 1 Release connection to logger 4 Minimize view 2 Freeze statistic 5 Monitor inte...

Страница 144: ...SUITE 144 Freeze statistic Continue statistic Display remote statistic counter Statistic since the start of the tool and connection to the datalogger Display local statistic counter Statistic since la...

Страница 145: ...necessary to do this Start the Convert tool of the XORAYASuite Starting 1 Add DLI file to list 6 Open selection in Viewer 2 Remove selected DLI files from list 7 Export settings 3 Move selection up 8...

Страница 146: ...order View log files in the Viewer tool Select one or multiple rows in the list by using the Shift and Ctrl key Click Open selection in Viewer 6 Select or deselect log files in the list Select the re...

Страница 147: ...rt Recorded log files are converted 9 Cancel convert 10 Open result DLI file Cancel conversion Click Cancel convert 9 or In the Convert menu click Cancel Open converted files After the successful conv...

Страница 148: ...Start the Firmware Update tool of the XORAYASuite Starting Connect to the desired datalogger Connecting the datalogger 1 Release connection to logger 3 Open SWU XSWU file 2 Start Hdd logging 4 Launch...

Страница 149: ...to restore the last datalogger configuration 5 Reset software Repeat the firmware update If the update fails click button 5 to reset the user interface to the initial state Activate licenses Activati...

Страница 150: ...cess to the XORAYAToolkit a collection of commands optimized for script oriented application Connect the datalogger to the PC Connecting the datalogger to the PC Turn on the datalogger Start the TK Co...

Страница 151: ...s XHddErase Deletes sessions from datalogger or formats the storage medium XHddLog Starts stops data recording in HDD mode or sets a snapshot XConfig Reads overwrites the datalogger configuration or c...

Страница 152: ...ction as required 5 14 1 Changing the numbering system For numerical values in text boxes you can switch the display between three numbering systems Already entered values are converted accordingly if...

Страница 153: ...er Click an X in the bottom row of a byte 1 once or twice to set the desired bit to 0 or 1 Highlight an X in the top row of a byte 2 and enter one hexadecimal digit to specify the half byte Highlight...

Страница 154: ...nd Convert Click Browse for folder 3 to select the Path Path is not available in the Configuration tool because the settings are saved on the datalogger itself Enter the desired Filename Special attri...

Страница 155: ...ut formats Check the settings of the selected output format 3 Filter the exported interface channels 4 Special attributes You can also separately change the original filename for each export filter by...

Страница 156: ...ater reuse Enter a name in the text box Export settings 8 Click Save this export setting 9 Load export setting Select the desired export setting in Export settings 8 Delete export setting Select the d...

Страница 157: ...ically 8 Manage signal lists 3 Sort by ID 9 Show signal details 4 Find previous 10 Signals overview 5 Search box 11 Signal details 6 Find next Add signals to signals overview 10 Click Signal descripti...

Страница 158: ...details 11 Click Add this signal 7 Manage signal lists 8 is activated 8 Manage signal lists 13 Add signal to list 10 Signals overview 14 Delete signal from list 11 Signal lists 15 Find signal 12 Add...

Страница 159: ...from signal list 11 in the signals overview 10 Select the signal in the signal list 11 Click Find signal 15 Storage location for signals signals overview and signal lists Added signals are stored on t...

Страница 160: ...figuration Online Logging and Viewer Here load description files and assign them to signal groups Supported description file types DBC LDF FIBEX XML A2L AUTOSAR ARXML 1 Add new signal group 6 Interfac...

Страница 161: ...r combined conditions are met Signal list Raise trigger if the datalogger detects one of these signals on the data buses Value compare 1 Apply trigger 7 Parenthesize selection 2 Cancel trigger configu...

Страница 162: ...cording to the rules of Boolean algebra the AND operator precedes the OR operator You can influence precedence by parentheses Add parentheses Click the desired conditions and operators to mark them bl...

Страница 163: ...o be sent Click Apply trigger 1 The value compare trigger is stored on the datalogger Signal list 1 Apply trigger 2 Cancel trigger configuration Add signal list trigger Select the check boxes of the d...

Страница 164: ...k and drag over an area to zoom in Double click to jump to the corresponding period in the Data panel of the Viewer tool Click the timeline 2 to display arrows which allow you to move in small steps t...

Страница 165: ...which represents the left clicked position Change the visibility of the green time pointer which represents the right clicked position Connect the graph points as lines curves stairs or do not connect...

Страница 166: ...l XAA for GNLog XAA GNLog RS 232 Event System DLT Autosar V4 0 DLT DLT Event System System Events TXT Event System Raw for RS232 RawSocket RAW RS 232 RawSocket Event CSV for Analog CCP PSI5 CSV DiagCC...

Страница 167: ...Off ShowDebug Write debug information Off ShowSystem Write messages of the system interface Off ShowMediaConfig Write entire configuration of the interface channels On ShowFormatDescription Show basic...

Страница 168: ...or further processing by CARMEN Off UseEcosCompatMode Do not write falling edges of button triggers possibly desired for compatibility reasons Off WriteOneFilePerInterface Write one file for each inte...

Страница 169: ...e size in MB 100 Extension x File extension raw TimestampPrefix Write timestamp prefix for each message Off AllowMarker Write events as markers Requirements TimestampPrefix must be On Event interface...

Страница 170: ...on Default DoJPEG Write images in JPEG format On DoMPEG Write videos in MPEG 2 format On DoH264 Write videos in MPEG 4 H 264 format Off 5 15 14 MDF Export Setting Description Default a2l_file_alternat...

Страница 171: ...circuit Bent connector pins pose a short circuit risk This can lead to abnormal behavior or destruction of the datalogger Likewise devices connected to the measurement setup may be also compromised M...

Страница 172: ...housing Do not operate the datalogger outdoors Do not operate the datalogger outside the specified temperature range Turn off the datalogger and disconnect it from the power supply before you start c...

Страница 173: ...should maintenance and repairs be required Upon malfunction or defect return the datalogger without any accessories to X2E GmbH You can find the address on page 2 of this manual Before submission plea...

Страница 174: ...ical and Electronic Equipment Act ElektroG which applies in Germany obliges every manufacturer to create a reasonable option for returning old B2B devices X2E cannot take back so called historical dev...

Страница 175: ...them you as the end user are legally obliged to remove them before disposal and dispose of them separately Deletion of personal data X2E expressly points out that the customer is responsible for dele...

Страница 176: ...y current consumption Max 1 mA at 12 V Dimensions H x W x D 70 x 255 x 207 mm with impact protection Housing protection type IP 20 NEMA Type 1 Pollution degree Pollution degree 3 Altitude Max 2000 m A...

Страница 177: ...Position Threshold 0 3 3 V 1 5 V 2 12 V 3 24 V 8 2 3 LIN Position Power supply Vi Internal Ve External Use the internal power supply of the LIN measurement card only if the connected LIN device uses...

Страница 178: ...show the external view of the datalogger contacts 8 3 1 10x CAN 3M 10220 M218 PE 2x spacer bolt 3M 3341 31 Pin Function 1 CAN 1 High 2 CAN 1 Low 3 CAN 2 High 4 CAN 2 Low 5 CAN 3 High 6 CAN 3 Low 7 CAN...

Страница 179: ...M Pin Function 1 2 FR BM A 3 GND 4 FR BM B 5 6 7 FR BP A 8 FR BP B 9 8 3 3 8x RS 232 3M 10220 5212 PL 2x spacer bolt 3M 3341 31 Pin Function 1 RX 8 2 TX 8 3 RX 7 4 TX 7 5 RX 6 6 TX 6 7 RX 5 8 TX 5 9 R...

Страница 180: ...3M 10214 5212 PL 2x spacer bolt 3M 3341 31 Pin Function 1 A 6 N 2 A 5 N 3 A 6 P 4 A 5 P 5 A 4 N 6 7 A 4 P 8 A 3 N 9 A 2 N 10 A 3 P 11 A 2 P 12 A 1 N 13 14 A 1 P 8 3 5 7x LIN D SUB 9 M Pin Function 1...

Страница 181: ...pacer bolt 3M 3341 31 Pin Function 1 LIN 1 2 LIN 2 3 LIN 3 4 LIN 4 5 LIN 5 6 LIN 6 7 LIN 7 8 LIN 8 9 LIN 9 10 LIN 10 11 LIN 11 12 LIN 12 13 LIN 13 14 LIN 14 15 LIN 15 16 LIN 16 17 LIN 17 18 LIN 18 19...

Страница 182: ...3 7 6x 1000Base T1 3x HARTING ix Industrial type A Pin Function 1 CH 2 P 2 CH 2 N 3 GND 4 5 6 CH 1 P 7 CH 1 N 8 GND 9 10 11 CH 4 P 12 CH 4 N 13 GND 14 15 16 CH 3 P 17 CH 3 N 18 GND 19 20 21 CH 6 P 22...

Страница 183: ...ype A Pin Function 1 CH 2 P 2 CH 2 N 3 GND 4 CH 4 P 5 CH 4 N 6 CH 1 P 7 CH 1 N 8 GND 9 CH 3 P 10 CH 3 N 11 CH 6 P 12 CH 6 N 13 GND 14 CH 8 P 15 CH 8 N 16 CH 5 P 17 CH 5 N 18 GND 19 CH 7 P 20 CH 7 N 21...

Страница 184: ...r M8 Series 718 F Pin Function 1 D 1 2 GND 3 D 2 4 GND 8 3 10 4x Digital In HARTING ix Industrial type B Pin Function 1 D 4 2 3 D 1 4 5 D 2 6 D 3 7 8 9 GND 10 8 3 11 Power Trigger Wake Conec D SUB Com...

Страница 185: ......

Страница 186: ......

Страница 187: ......

Страница 188: ......

Страница 189: ......

Страница 190: ......

Страница 191: ......

Страница 192: ...X2E GmbH Grosse Ahlmuehle 19 76865 Rohrbach Germany Phone 49 6349 99599 200 E mail xoraya x2e de Internet www x2e de Wiki wiki x2e de...

Отзывы: