DiagCCP > Trigger:
1 Add trigger
4 Delete trigger
2 Trigger type
5 Move trigger up
3 Edit trigger
6 Move trigger down
Here, you create conditions that trigger the following pre-defined actions:
▪
Start CCP logging
▪
Stop CCP logging
Start and stop without trigger conditions
Even when you do not create trigger conditions, the CCP
recording, provided it is activated, starts and stops
automatically at the beginning or ending of the data
recording in online mode or HDD mode.
Configure triggers:
On the header of the desired trigger action, click
Add trigger
(1)
.
Select the desired
Trigger type
(2)
.
Create a single condition or multiple combined conditions for this
trigger. (
➔
If required, repeat the above steps for further triggers.
Number of configurable triggers
You can configure a maximum of ten triggers per
DiagCCP interface channel.