Quick Guide for Stick Logger (WiFi)
Product Model: LSW-5
Notice:
Please read this manual carefully before using products and keep it in the place where O&M
providers can easily find.
Due to product upgrade and other factors,the content of this manual might change from time to
time.Please take actual product as standard and get latest manual from www.solarmanpv.com
or sales. Unless otherwise agreed herein,this manual will only be used as guidance.Any
statement,information or suggestion in this manual will not take any form of responsibility.
Without written permission,any content of this document(partly or entirely)cannot be extracted,
copied or transmitted in any form by any company or individual.
Warning:
1.Please power off during the installation.
1.Logger Installation
Interface 1
Fix inverter and logger with the screws. Please refer to the installation steps for
DB9 interface.
Fix logger to inverter com interface according the diagram.
Interface 2
Fix inverter and logger with aeronautical head.
Install the logger according to guide slot.
Tighten the cap in a clockwise direction.
Interface 3
Fix inverter and logger with USB head.
Install the logger according to guide slot.
Tighten the cap in a clockwise direction.
2.LED Indicator Lights Instruction
Instruction
Implication
Light
Communicate with router
Communicate with inverter
Logger running status
1.Light off: Connection to the router failed.
2.On 1s/Off 1s (Slow flash): Connection to the router succeeded.
3.Light on: Connection to the server succeeded.
On 100ms/Off 100ms (Fast flash): Quick network distribution.
1.Light on: Logger connected to the inverter.
2.Light off: Connection to the inverter failed.
On 1s/Off 1s (Slow flash): Communicating with inverter.
1. Light off: Logger runs abnormally.
2.On 1s/Off 1s (Slow flash): Logger runs normally.
3.On 100ms/Off 100ms (Fast flash): Restore factory setting.
The normal operation status after the stick logger powered on:
1
、
Successful connection with the server: NET light keeps on after the stick logger powered on.
2
、
Normal operation: READY light flashes.
3
、
Successful connection with the inverter: COM light keeps on.
3.Abnormal Status Processing
If the data on platform is abnormal when the stick logger is running, please check the table below and according to
the status of indicator lights to complete a simple troubleshooting. If it still can not be resolved or indicator lights
status do not show in the table below, please contact our Customer Support.
(Note: Please using the following table query after power-on for 2mins.)
NET COM READY
Fault Description
Fault Cause
Solution
Any
status OFF
Slow
flash
Communicate
with inverter
abnormal
1.Connection between stick
logger and inverter loosen.
2.Inverter does not match
with stick logger’s
communication rate.
1.Check the connection between stick
logger and inverter. Remove the stick
logger and install again.
2.Check inverter’s communication rate
to see if it matches with stick logger’s.
OFF
ON
Slow
flash
Communicate
with router
abnormal
1.Stick logger does not have
a network.
2.WiFi signal strength weak
1.Check if the wireless network
configured.
2.Enhance WiFi signal strength.
Slow
flash
Slow
flash
ON
Connection to
router normally,
connection to
server abnormally
1.Router network abnormal.
2.Server point has been
modified.
3.Network limited.
1.Check if the router has network.
2.Check router settings.
3.Contact Customer Service.
OFF
OFF
OFF Power supply
abnormal
1.Connection between stick
logger and inverter loosen or
abnormal.
2.Inverter power insufficient.
3.Stick Logger abnormal.
1.Check the connection, remove the
stick logger and install again.
2.Check inverter output power.
3.Contact Customer Service.
Fast
flash
Any
status
Any
status
Bluetooth
network
distribution
Normal
1.Exit after 5min.
2.5s long press for rebooting.
3.10s long press for restoring.
Any
status
Any
status
Fast
flash
Restore factory
setting
1.Exit after 1min.
2.5s long press for rebooting.
3.10s long press for restoring.
Normal
Warning: Please make sure the stick logger is working properly
before you leave the site. If there is anything abnormal, please
do not leave the site and contact customer service at the first time.
Customer service number: 400-181-0512
If you have any technical queries about our products, please contact
us and provide the following information:
1. Product model and serial number of stick logger.
2. Product model and serial number of connected inverter.
Thank you for your support and cooperation!
Quick Guide
4.Monitoring Platform
1.Download
If you are an end-user, it is recommended to use SOLARMAN Smart. Scan the QR
code below to download the APP or go to Android Market/App Store and search
“SOLARMAN Smart”to download.
Web entrance: https;//home.solarmanpv.com
SOLARMAN Smart