12
X-Oven.2 / January 2017
Installation
The X-Oven.2 model has been designed to be installed and utilized in indoor
professional kitchens with aeration as by law enacted or outdoor.
There are two alternative types of installations possible
indoor
:
•
Installation under extractor hood
•
Installation under extractor hood with exhaust pipe connector
In both types of installations it is mandatory to place the product under an
extractor hood.
The product can be also used
outdoor
obtaining the same performances
declared and cooking result.
SAFETY DISTANCES
In an indoor environment, the X-Oven.2, must be positioned at a minimum of
5 cm from the walls or other appliances in order to permit proper ventilation
and guarantee a safe installation, see
Chart 3
. It is mandatory to keep inflam-
mables materials at a minimum of 5 cm distance from the product.
Chart 3
- Safety distances
Right side
50 mm
Left side
50 mm
Front side
50 mm
Back side
50 mm
Top side
(Fire breaker – Extractor hood intake)
> 250 mm
< 500 mm