ON-SCREEN MENU

•  VU meter indicates audio channels/levels 

•  Battery status of the unit

•  Unit Standby mode – ensure this is always set to OFF to receive a signal

•  EDID Setting to change EDID to match source device ((See EDID section of this manual) 

NOTE: A static green Status LED on the front panel of both TT-GEN-4K and TT-SIG-4K indicates correct signal reception 

and unit operation.

A blinking Status light illustrates an EDID error within the signal, while no Status light suggests no signal is being 

received, the link has been lost, or HPD (Hot Plug Detect) is not present.

On-Screen Menu

The TT-GEN-4K Signal Generator recalls operation from the previous use so settings such as the last pattern and timing selected and 

will appear automatically on start-up.

4KYUV420x50

Pressing L/R arrows will cycle through timing settings, with the details of the timing along the bottom of the screen. Pressing up/down 

buttons will cycle through the patterns retaining the last timing selected.

Operation of both the TT-GEN-4K and TT-SIG-4K are the same whether receiving/not receiving a signal with the 

Menu/Enter

 button 

serving the dual purpose of accessing the main menu to display the information/options and confirming the selection of a function.

The main menu displays for approximately 5 seconds before returning to ‘normal/display mode’ if no button is pressed.

Up/Down

 cursor buttons cycle between the pre-set or stored signal patterns or parameters and < > cursors scrolling through the 

options or values to change.

Cancel

 exits the menu screen and returns to normal/display mode.

i. TT-GEN-4K Timing Signal Generator

 

Pressing the Menu/Enter button always displays ‘Timing’ as the first the first screen in the menu.

  

Timing:

4KYUV420x50

1.  Timing: 1 Auto, 32 preset and 10 user-defined timing signal pattern settings

ColorSpace:

YUV420

2.  Color Space: Auto, RGB, YUV444, YUV422

Содержание TT-KIT-4K

Страница 1: ...280 WYRE 9973 Thank you for choosing this WyreStorm product Please read these instructions carefully before installing to avoid complications later Instruction Manual TT KIT 4K 4K Test Kit Comprising...

Страница 2: ...and heed all warnings 3 Do not expose this apparatus to rain moisture sprays drips or splashes and ensure that no objects containing liquids are placed on the apparatus including cups glasses and vase...

Страница 3: ...ations Basic Setup and Operation On Screen Menu i TT GEN 4K Timing Signal Generator ii TT SIG 4K Source Signal Analyzer Advanced Operation via PC software TT GEN 4K 4K Timing Signal Generator i Genera...

Страница 4: ...to test a signal over a defined period of time enabling the installer to leave the device unmanned all day night to analyze every minute hour of use for an invaluable time and cost saving method of t...

Страница 5: ...ergy efficient 2 inch OLED screen to display signal data with on screen user interface Screen also displays video from connected device Unmanned monitor mode on enables independent assessment of signa...

Страница 6: ...t HDMI Audio Format Supported PCM only Audio Output HDMI Audio Bit 16bit 20bit 24bit Audio Sample Rate 32K 44K 48K 88K 96K 176K 192K Audio Channels Supported 8 Audio Format Supported PCM only Audio Im...

Страница 7: ...using Metal Control Front panel push button USB RS 232 Certification CE FCC RoHS Compliant Panel Description TT GEN 4K 4K Timing Signal Generator Front 1 24mm 0 95in Active Matrix OLED AMOLED screen t...

Страница 8: ...ower switch On Off 1 2 3 4 5 Panel Description TT SIG 4K 4K Source Signal Analyzer Front 1 55mm 2 2in OLED screen to displays test information menu options settings and video received connected HDMI d...

Страница 9: ...nstallation scenarios including HDMI cables installed in wall and HDMI devices such as matrices switchers splitters and displays the TT KIT 4K can also test HDMI signals distributed through HDBaseT or...

Страница 10: ...hrough a Wall Plate Using TT GEN 4K and TT SIG 4K RS 232 USB to PC RS 232 USB to PC TT SIG 4K TT GEN 4K In wall HDMI Plates KEY HDMI RS 232 USB Testing HDMI Through a Splitter Using TT GEN 4K and TT S...

Страница 11: ...ce Devices with No Display Present TT SIG 4K replaces display RS 232 USB to PC TT SIG 4K KEY HDMI RS 232 USB Testing HDMI Through HDBaseT or Similar Matrix and Receiver Note HDMI output or matrix rece...

Страница 12: ...Make sure of firm HDMI connection to devices but do not force connectors into ports Always use good quality reliable high speed Category 2 HDMI cables that support 4K within distance specification of...

Страница 13: ...o the next previous signal pattern in the menu while pressing Up Down cycles through previous next timing generation options to output Once the Generator has initialized we recommend using the Up Down...

Страница 14: ...cycle through timing settings with the details of the timing along the bottom of the screen Pressing up down buttons will cycle through the patterns retaining the last timing selected Operation of bot...

Страница 15: ...to 32k 44K 48k 88k 96k 176k 192k 7 Auto Resolution On Off 8 Audio Channel Number Auto 2ch 3ch 4ch 5ch 6ch 7ch 8ch 9 Output standby Off On Useful for simulating a power cycle of a source device when co...

Страница 16: ...no information Pressing the Menu Enter button always displays Signal Info as the first the first screen in the menu If the TT SIG 4K Source Analyzer is not receiving a signal the blue No Signal scree...

Страница 17: ...to access the full functionality of the Generator and Analyzer via a PC including the display of signal information and detailed configuration of signal parameters within their respective interfaces...

Страница 18: ...t device 9 Set desired signal parameters to be included within test conditions using the tabbed sub menus of the software TT GEN 4K Timing Signal Generator Interface A B C D E F G K L M N O H I J i Ge...

Страница 19: ...o selected user defined number E Press to read status data from the Generator and update status iii Pattern Select Menu The Pattern Select sub menu page offers a wide variety of standard and unique vi...

Страница 20: ...cted color space is fixed to RGB 4 4 4 and color depth fixed to 24bit When HDMI 2 0 4K 50 60Hz is selected color space is fixed to YUV 4 2 0 B HDCP ON OFF Allows the user to add or remove HDCP 1 4 to...

Страница 21: ...H A Click drop down options to select where to read EDID from fixed TV EDID or one of the 10 user defined save slots B Click the to read the selected EDID of connected TV screen or any previously sav...

Страница 22: ...t Serial Port number D Search Machine Click to initialize search for connected TT SIG 4K via USB or RS232 to PC E Turn On Off Output port ensure this is set to ON for the unit to pass a signal F Volum...

Страница 23: ...ew window to display signal pattern or video signals NOTE Previewing images from the source device to a PC is not recommended using RS 232 due to bandwidth limitations of the serial port approximately...

Страница 24: ...Time slots is 2040 with each Time slot able to be set to 1 255 seconds or minutes 2 Set method of trigger i e when the software should report an event whether event set to detect differences in frame...

Страница 25: ...eset EDID or 10 user defined save slots 2 Click to read EDID of connected display or any previously saved user defined EDID 3 EDID data will appear in the window to the left NOTE If no EDID appears ch...

Страница 26: ...ever possible Check unit Status LED on units are lit to indicate correct functionality NOTE Status lights for TT GEN 4K and TT SIG 4K should be static 4 Resolution If no signal reduce the resolution o...

Страница 27: ...adequate insurance and preferably in the original packaging Please include a document or letter detailing the reason for return and include a daytime telephone number and or email address where you ca...

Страница 28: ...or re install previously installed equipment travel to and from service location loss of or damage to media images data or other recorded stored content The items listed here are not exclusive but are...

Страница 29: ...INSTALLATION NOTES...

Страница 30: ...A Office Unit 22 Ergo Business Park Swindon Wiltshire SN3 3JW UK Tel 44 0 1793 230 343 WyreStorm Technical Support US 1 844 280 WYRE 9973 UK 44 0 1793 230 343 Email support wyrestorm com WyreStorm Tec...

Отзывы: