17
Technical Support: [email protected] US: +866 677 0053 EU: +44 (0) 1793 230 343
ADV
AN
CE
D OPE
RA
TI
ON
IR code Set
The MX-0808-HDBT supports third party control systems and
learning handsets. Pressing the
IR SET
button in the COM
CTL main screen allows access for users to enter new IR code or
modify existing code and assign it to inputs and outputs so control
using third party systems is possible.
A
Receives the specific IR code used to operate the Matrix via
remote control. Can contain a
custom
or
data
code
. Third
party remote control codes are also shown.
B
IR code can also be
input manually
in the event it is
unreadable.
01
Press to automatically
read
the current IR code from the
device.
02
The resulting code appears in the
wait to modify code
section where
output
and
input
code can be edited if
necessary (for example if using third party control systems)
Note: All input/output boxes should contain code. If
inputting manually, make sure there is no repetition of code.
All code should be different.
03
Write
the code from the
Modify
section to the
device
to
authorise remote control usage.
Note:
Modified code can be saved as a
Custom code
and read
directly from a library of stored custom codes.
11
B
A
B
02
04
01
03
Modify Section - Control Commands and Code
Code input in the
Input/Output
section and
Control code
section must follow a strict format for the command to be
understood by the system.
For reference - the command format to be input is:
Type
“Cir”
- followed by a “space” - then the “code number” - and
hit the
”enter”
key.
For example
Cir 39
+
”enter”
(equals a hex code of 63 69 72 20
33 39 0D 0A)
Note:
Such a command will tell the matrix to select the next
Input
source
for
Output 4
02
04
MX-0808-HDBT Control Code
Output 1 < “08” “09”>
1 “00”
2 “01”
3 “02”
4 “03”
5 “04”
6 “05”
7 “06”
8 “07”
Output 2 < “18” “19”>
1 “10”
2 “11”
3 “12”
4 “13”
5 “14”
6 “15”
7 “16”
8 “17”
Output 3 < “28” “29”>
1 “20”
2 “21”
3 “22”
4 “23”
5 “24”
6 “25”
7 “26”
8 “27”
Output 4 < “38” “39”>
1 “30”
2 “31”
3 “32”
4 “33”
5 “34”
6 “35”
7 “36”
8 “37”
Output 5 < “48” “49”>
1 “40”
2 “41”
3 “42”
4 “43”
5 “44”
6 “45”
7 “46”
8 “47”
Output 6 < “58” “59”>
1 “50”
2 “51”
3 “52”
4 “53”
5 “54”
6 “55”
7 “56”
8 “57”
Output 7 < “68” “69”>
1 “60”
2 “61”
3 “62”
4 “63”
5 “64”
6 “65”
7 “66”
8 “67”
Output 8 < “78”
“79”>
1 “70”
2 “71”
3 “72”
4 “73”
5 “74”
6 “75”
7 “76”
8 “77”
If the control command is sent successfully, the current
output
state
selected will feedback to show the
input port
selected. The
return status format is as follows:
“S”
Output port
Input port
1st byte
2nd byte
3rd byte
For example: if
Cir 44
“enter”
is sent successfully to the matrix,
it will feedback
“s55”
– meaning
Output 5
has selected
Input 5
.