RS232 setting

Should third party control be required, please see below for control 
system configuration and  hex code input. The RS232 connection 
on the matrix is female QB9  Users can use a USB to RS232 
cable or a direct male to female serial cable.

5

4

3

2

1

9

Ground

RXD TXD

8

7

6

Female connector - 9 holes

1

2

3

4

5

6

Ground

RXD

TXD

7

8

9

Male connector - 9 holes

RXD

 Receive serial data from PC

TXD

 Transmit serial data to PC

Baud rate 

9600bps

Data bits 

8bits

Parity 

None

Stop bits 

1

Flow control 

None

Com Port Setting

NET CTL - LAN Control

For control of the matrix over a network through an internet 
service provider. 
 
When NET CTL is first run on a PC, the text file ‘NETCTL.TXT’ will 
be created to store backup matrix information such as the MAC 
address of the matrix, the IP address and the matrix name etc.

Double click 

NETCTL.exe

 to run the software and search for a 

device.  Any new device detected will appear as an 

IP address

while previously used devices will be 

named

.  Click 

Read Device

 

to access.   
 

Note: 

 If you want to change the device name, 

right click

 on the 

device name or IP address and select 

rename

 from the drop box.  

Rename and save. 
 
Double click the matrix to access the system – provided you are 
connected to the internet, a web browser will open up, prompting 
a log in.  Enter the default password 

‘0000000000’

 to log in to 

network control and you will be directed to the matrix control 
screen.

 
Alternatively, you can open a web browser and enter the IP 
address to be directed to the matrix control screen. 
 

Note: 

 your matrix IP address can also be obtained through the 

touch screen by following: 
 
Main menu         Info          navigate to the IP column.

As with COM CTL software control and remote control of the matrix 
-         confirms the current input/output selections from

01

02

Reassigning IP Address

The appearance of the prompt ‘Assign IP’ suggests automatic IP 
assignment has been unsuccessful so you will need to assign 
manually. 

Double click ‘

Assign IP

’ to open up the IP dialogue box and 

reinput your IP address, Subnet, Gateway and Mac addresses if 
need be.  Click OK to confirm.  Click 

“Search”

 and 

“Read Device”

  

to prompt NETCTL to display the matrix correctly and allow access 
to network control.

01

02

Содержание MX-0808-HDBT

Страница 1: ... you for choosing this WyreStorm product Please read these instructions carefully before installing to avoid complications later Instruction Manual 8 x 8 Output Full HD Matrix Switch Part Number MX 0808 HDBT ...

Страница 2: ... HDCP source encryption The use of HDBaseT one cable technology enables the MX 0808 HDBT to deliver HD audio and video multiple control options and high speed internet access through a single Cat 5e 6 7 cable with a transmission distance of up to 100m 328ft for 1080p The system has versatile control with users able to choose from several methods of controlling the matrix Infrared IR emitters and r...

Страница 3: ...cing to qualified service personnel WARNING To reduce the risk of fire electric shock or product damage Each output features integrated single RJ45 outputs Reads and copies EDID from connected devices 3D compatible and fully supports all high definition resolutions 1080p 1080i 720p Each output card offers RS232 pass through Each port supports both HDMI and DVI signals Choose from seven switching m...

Страница 4: ... 5 Specifications 6 Front Panel 01 Touch panel 02 Remote control IR sensor 03 Power on off switch 7 Rear Panel 04 IR extension port for control when the Matrix is out of view such as in a rack or enclosed shelving system 05 DIP switch 06 RS485 port alternative control of the matrix via RS485 cable 07 LAN port for controlling the Matrix remotely over an IP network 08 IR TX Emitter ports numbered 1 ...

Страница 5: ... 44 0 1793 230 343 FRONT PANEL REAR PANEL 01 02 03 04 05 06 07 08 09 11 HDBaseT Single Cat5e 6 7 Display Receiver Part Number RX 100IR HDBT In wall HDBaseT Single Cat5e 6 7 Display Receiver Part Number RX 100IR HDBT IW Front Panel Rear Panel 12 13 14 15 16 17 10 ...

Страница 6: ...pushed securely into each port and supported by the connector strain relief clip to prevent them from becoming loose The quality of termination for your RJ45 is essential Poor quality terminations lead to intermittent performance and longer install times ATTENTION We strongly recommend using the supplied mounting brackets to secure the MATRIX and the accompanying TRANSMITTER DISPLAY RECEIVER balun...

Страница 7: ...essing your saved memory setting number See Save Mode for details on setting switch save observe preview setting A C MS EQ M1 M2 M3 switch save C M1 M2 M3 switch save observe preview setting A C MS EQ M1 M2 M3 switch save observe preview setting A C MS EQ M1 M2 M3 Save Mode When you have decided on your combination of source and display you can save your choice by entering the save mode and assign...

Страница 8: ...unit Pressing the button three times again to reverts back to default 0x00 setting Please note changing the System Code is only necessary if you are using two identical units within close range of the IR signal If using in different parts of the same room it is likely that you will not need to change the setting Remote control at the Display end remotely When controlling the matrix remotely from t...

Страница 9: ...n them For example if output 3 is selected followed by input 8 the EDID from output 3 will be copied to input 8 2 As above but the selection of Limited Copy excludes Deep Colour from the EDID to avoid discrepancies in colour between input and output This can be useful if the display still shows signs of noise or interference The exclusion of Deep Colour from the EDID reduces bandwidth to allow the...

Страница 10: ...t of 1080p 5 1 audio 5 As above but inputs are set to output to a limit of 1080p 7 1 audio 6 As above but inputs are set to output to a limit of 1080i 2 channel stereo audio For example Support 1080i stereo TV2 Support 1080P stereo Support 1080P7 1 Audio AVR TV1 Video 1080i Audio stereo TV2 Video 1080i Audio stereo Video 1080i Audio stereo AVR Fix EDID 1080i 2CH TV1 Video and Audio unsupported TV2...

Страница 11: ...ems are less susceptible to electrical interference UTP transmission can still be significantly reduced if cable runs contain stranded cable bends kinks patch panels or wall outlets Straight cable runs using solid core UTP are recommended If cable runs are reaching the upper limit of receiver capabilities boost the signal by using a WyreStorm HDBT extender set of transmitter and receiver HDBaseT E...

Страница 12: ...R or IP settings Note A red dot next to an output illustrates that the corresponding RJ45 output port is in single output mode switch save observe preview setting A C MS EQ M1 M2 M3 switch save observe preview setting A C MS EQ M1 M2 M3 A C MS EQ M1 M2 Calibrating screen sensitivity Should a loss in touch screen sensitivity become noticable we recommend recalibrating the screen by pressing and hol...

Страница 13: ...rix Note To see the firmware version currently used in the system power off and repower while the matrix is connected to COM CTL The firmware version and creation date will be displayed together with the normal output state of the matrix 06 Shows if the matrix is connected or disconnected to the Com Port and communication is enabled Selection between ports is available by pressing the Com Port Sel...

Страница 14: ... picture stability Choose from a db range of 32 settings See 12 07 UTP Output Set The UTP output settings can be changed in the screen but will NOT take effect in the matrix itself This feature of the software is for dual cable PRO matrix models only HDBT uses single cable transmission 09 Set IP TThe matrix can also be controlled over LAN Pressing the SET IP button in main COM CTL screen gives acc...

Страница 15: ...ously used devices will be named Click Read Device to access Note If you want to change the device name right click on the device name or IP address and select rename from the drop box Rename and save Double click the matrix to access the system provided you are connected to the internet a web browser will open up prompting a log in Enter the default password 0000000000 to log in to network contro...

Страница 16: ...nd read directly from a library of stored custom codes 11 B A B 02 04 01 03 Modify Section Control Commands and Code Code input in the Input Output section and Control code section must follow a strict format for the command to be understood by the system For reference the command format to be input is Type Cir followed by a space then the code number and hit the enter key For example Cir 39 enter...

Страница 17: ...ecific output EDID from a particular display for example 01 02 03 04 05 A Read Status Command The command length of the read status is 4 bytes Type bc followed by a space and hit the enter key For example bc enter Note Such a command will tell the matrix to feedback the current status of all outputs See below for status format 16 bytes 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 r n s X1 X2 s X3 X4 s X...

Страница 18: ...een patch panels or wall outlets Such use reduces signal strength we recommend solid core straight through connections to be used wherever possible 6 Resolution If you reduce the resolution of the source do you get a picture If so this suggests a discrepancy between source and display resolution or a bandwidth capacity issue with your cable Check that your inputs and outputs share the same resolut...

Страница 19: ...s work through the AV receiver Check the operation of each source individually Bandwidth 1 If using a graphics based source such as a PC Mac media server make sure the source resolution is set to a maximum of 1080p 50Hz Higher resolutions available for graphics based systems require higher bandwidth that may affect transmission of signals as well as incompatibility with devices IR 1 Check you are ...

Страница 20: ... new USB power cables overcome the problem of having a second mains outlet behind the TV These useful leads draw the 5v from the USB socket on the TV to power the receiver this also means that the receiver 15 FAQs is only powered when the TV is on making the system more environmentally friendly Do I need to use 1 or 2 cables Using our conventional pro TMDS transmission method the Video Audio is se...

Страница 21: ...or refurbished product Limited warranty period All WyreStorm products are covered by a 2 year PARTS and LABOUR warranty During this period there will be no charge for unit repair replacement of unit components or replacement of product if necessary The decision to repair or replace will be made by the warrantor The purchaser must mail in the product during the warranty period This limited warranty...

Страница 22: ... 677 0053 EU 44 0 1793 230 343 INPUT REFERENCE LOG INPUT Input number on Matrix Source Location Source Details Source resolution audio settings Cable Number 1 2 3 4 5 6 7 8 WyreStorm 08x08 HDBT Matrix INPUT installation reference log 21 Reference Logs ...

Страница 23: ...US 866 677 0053 EU 44 0 1793 230 343 OUTPUT REFERENCE LOG OUTPUT Output number on Matrix Output Location Display Details Display Resolution Audio Settings Cable Number 1 2 3 4 5 6 7 8 WyreStorm 08x08 HDBT Matrix OUPUT installation reference log ...

Страница 24: ...l 901 384 3575 Fax 901 384 3574 Unit 22 Ergo Business Park Swindon Wiltshire SN3 3JW UK Tel 44 0 1793 230 343 Fax 44 0 1793 230 583 WyreStorm Technical Support US 86 6677 0053 UK 44 0 1793 238 338 Email support wyrestorm com We reserve the right to change specification or product dimensions at any time ...

Отзывы: