4.2 INTERNAL SETTING
4.2.1 Display Segment Check
User can enter this function to check to see if the display and backlight (if purchased) are functioning properly.
a.
Scale is off
b.
Press and hold TARE, then press ON/ZERO
c.
Scale displays F.1
d.
Press TARE once
e.
Scale displays F.2
f.
Press MODE and all segments will light up to allow user to check the condition of display
g.
Press TARE for next function setup or ON/ZERO to restart the scale
4.2.2 Select Auto Power Off Setting
The scale is equipped with Auto Power Off Function. The scale will power off automatically if it is not used for 4 minutes.
Follow the below steps to enable/disable Auto Power Off Function.
a.
Scale is off
b.
Press and hold TARE, then press ON/ZERO
c.
Scale displays F.1
d.
Press TARE three times
e.
Scale displays F.4
f.
Press MODE to shift between 0._OFF and 4._OFF
-To enable Auto Power Off Function, press TARE when 4._OFF appears
-To disable Auto Power Off Function, press TARE when 0._OFF appears
g.
Press ON/ZERO to restart the scale or TARE for next function setup
4.2.3 Select Auto Tare Function
This scale is equipped with auto tare function which tares off the initial weight automatically when this function is
engaged. The tare weight is automatically cleared when everything is removed from platter.
a.
Scale is off
b.
Press and hold TARE, then press ON/ZERO
c.
Scale displays F.1
d.
Press TARE six times
e.
Scale displays F.9
f.
Press MODE to select between “Tr_on” or “TroFF”
-To enable Auto Tare Function, press TARE when Tr_on appears
-To disable Auto Tare Function, press TARE when TroFF appears
g.
Press ON/ZERO to confirm and restart the scale or TARE for next function setup