28
GB
Sliding door system for single and double leaf glass doors with SOFT-STOP
Wilh. Schlechtendahl & Söhne GmbH & Co. KG
Assembly
Track stop installation
Screw in damper 19 by hand.
Screw threaded pin 20 into case using a 3 mm
Allen key.
Carrier installation
Select gaskets and install carrier
Glass thickness
Gaskets
8 and 8,76 mm
4 x 3,2 mm
10 and 10,76 mm
4 x 2,2 mm
12 and 12,76 mm
4 x 1,2 mm
Remove backing foil
30
from adhesive pad
and stick gaskets
15
onto all four clamping
brackets
34
.
ATTENTION! Do not unscrew clamping
screws 31 completely!
Attach carrier plate 27 to respective clamping
plate using screws 28 and 3 mm Allen key.
Positioning carrier
ATTENTION: Before mounting, clean
the glass surfaces in the area of the clamping
with glass cleaners that are free of silicones
and oils. Due to the special properties of
laminated safety glass, we recommend gluing
the carriages additionally. When using VSG
with a pressure-neutral interlayer, the techni-
cal instructions for ESG apply. Position carria-
ge 3 on the door as shown in fig. The lift-out
protection 16 must face the outer edge of
the glass. Tighten clamping screw 31 using a
torque spanner with SW4 bit (12 Nm).
Version, left side
40
40
40
40
40
4
40
Version, right side
I
16
16
16
31
3
16 31
31
16
16
G
4x
H
30
31
27 28
34
34
34
15
17
17
20
19