22
Checkweigher
TROUBLESHOOTING & ERROR MESSAGES
Unit won’t power up:
Check diagnostic LED lamps on the Mother board.
GREEN LED
OFF
:
The Power Supply module is NOT receiving AC power.
•
Verify power source (Cords, Outlets, breakers).
•
If power source is good, the Power Supply module
may be damaged.
GREEN LED
ON
:
The Power Supply module is receiving AC power.
•
Check Power Supply module connection to
Mother board.
•
Power Supply module or Mother board may be
damaged.
Error Messages
Condition
ZERO / TARE Error:
•
Scale in motion during ZERO or
TARE.
•
See Page 4 & 5.
Scale Overload Error:
•
Scale weight is over capacity:
•
Remove weight from scale
Power Up Zero Error:
•
Scale weight exceeds 18% of scale
capacity on power up.