13
Technical Manual
Navigating Calibration Parameters
1. Use the
UP
and
DOWN ARROW
keys to find the parameter. Calibration
Parameters are displayed by the letter “P” preceding the parameter
number (Ex. “
P1.1, P1.2, P1.3 …
”).
2. Holding down the
UP
or
DOWN ARROW
key for more than 1 second will
scroll through the Calibration Sub-blocks for quicker navigation. (Ex.
“
P1.0, P2.0, P3.0 ...
”).
3. Press the
ENTER
key to select the parameter for editing.
Editing Calibration Parameters
1. Use the
UP
and
DOWN ARROW
keys to edit the parameter value.
2. Press
ENTER
to confirm the parameter value.
To edit a numeric value (Ex. Weight), use the
LEFT
and
RIGHT ARROW
keys to select the digit and the
UP
and
DOWN ARROW
keys to alter the
digit’s value. Press the
ENTER
key when done.
Example: Enter 20.0 (Note: Decimal point is determined by P1.2)
Exit & Save Calibration
1. Press the
LEFT
and
RIGHT ARROW
keys together.
2. The indicator will exit Calibration Mode and return to Weighing Mode. All
calibration information is saved.
In Calibration Mode, if no keys are pressed for 10 seconds, the scale
weight is displayed with a blinking “C” on the left-hand side.