Checkweigher Functions Sub-block 6.x
Parameter
Value
Description
P6.0
Check Mode
0 = Disabled
1 = Target <
2 = Target %
3 = Zero Check
4 = Entered
Target
Selects the type of Checkweigher Over/Under
function:
0 = Checkweigher functions are disabled
1 = Checkweigher acquires target value from scale
and OVER/UNDER is set from e/- weight
range.
2 = Checkweigher acquires target value from scale
and OVER/UNDER is set as a +/- % of target
value.
3 = Zero checkweighing, OVER/UNDER range is
set from e/- weight range. Checkweighing
is done from NET ZERO.
4 = Checkweigher OVER/UNDER range is
independently entered by the operator.
P6.1
Bar Graph
Configuration
0 = Dual
segment bar
graph.
1 = Bar graph
with large
accept.
2 = Single light
bar for
over/under
and accept. <
Controls how the Checkweigher OVER/UNDER
display functions.
1. Bargraph mode
2. Bargraph mode for OVER/UNDER with the
ACCEPT range as a single large indicator
bar.
3. OVER/ACCEPT/UNDER as large indicator
bars.
P6.2
ID Mode
0 = Disabled <
1 = Enabled
Enables the ID key to allow OVER/UNDER values
to be stored and recalled. Up to 100 products with
OVER/UNDER ranges can be stored.