WPI MPS-4 Скачать руководство пользователя страница 35

MPS-4

World Precision Instruments 

31

* Electrodes, batteries and other consumable parts are warranted for 30 days only from the date on which 

the customer receives these items.

WARRANTY

WPI (World Precision Instruments) warrants to the original purchaser that this equipment, including 

its components and parts, shall be free from defects in material and workmanship for a period of 

one year* from the date of receipt. WPI’s obligation under this warranty shall be limited to repair or 

replacement, at WPI’s option, of the equipment or defective components or parts upon receipt thereof 

f.o.b. WPI, Sarasota, Florida U.S.A. Return of a repaired instrument shall be f.o.b. Sarasota.

The above warranty is contingent upon normal usage and does not cover products which have been 

modified without WPI’s approval or which have been subjected to unusual physical or electrical stress 

or on which the original identification marks have been removed or altered. The above warranty will not 

apply if adjustment, repair or parts replacement is required because of accident, neglect, misuse, failure 

of electric power, air conditioning, humidity control, or causes other than normal and ordinary usage.

To the extent that any of its equipment is furnished by a manufacturer other than WPI, the foregoing 

warranty shall be applicable only to the extent of the warranty furnished by such other manufacturer. 

This warranty will not apply to appearance terms, such as knobs, handles, dials or the like.

WPI makes no warranty of any kind, express or implied or statutory, including without limitation any 

warranties of merchantability and/or fitness for a particular purpose. WPI shall not be liable for any 

damages, whether direct, indirect, special or consequential arising from a failure of this product to 

operate in the manner desired by the user. WPI shall not be liable for any damage to data or property 

that may be caused directly or indirectly by use of this product.

Claims and Returns

Inspect all shipments upon receipt. Missing cartons or obvious damage to cartons should be noted on 

the delivery receipt before signing. Concealed loss or damage should be reported at once to the carrier 

and an inspection requested. All claims for shortage or damage must be made within ten (10) days 

after receipt of shipment. Claims for lost shipments must be made within thirty (30) days of receipt of 

invoice or other notification of shipment. Please save damaged or pilfered cartons until claim is settled. 

In some instances, photographic documentation may be required. Some items are time-sensitive; WPI 

assumes no extended warranty or any liability for use beyond the date specified on the container

Do not return any goods to us without obtaining prior approval and instructions from our Returns 

Department. Goods returned (unauthorized) by collect freight may be refused. Goods accepted for 

restocking will be exchanged or credited to your WPI account. Goods returned which were ordered 

by customers in error are subject to a 25% restocking charge. Equipment which was built as a special 

order cannot be returned.

Repairs

Contact our Customer Service Department for assistance in the repair of apparatus. Do not return 

goods until instructions have been received. Returned items must be securely packed to prevent 

further damage in transit. The Customer is responsible for paying shipping expenses, including 

adequate insurance on all items returned for repairs. Identification of the item(s) by model number, 

name, as well as complete description of the difficulties experienced should be written on the repair 

purchase order and on a tag attached to the item.

Содержание MPS-4

Страница 1: ...WORLD PRECISION INSTRUMENTS MPS 4 Multichannel Perfusion System Serial No _____________________ www wpiinc com INSTRUCTION MANUAL 011720...

Страница 2: ......

Страница 3: ...Installation 6 Installation 6 Startup 6 Creating a New Perfusion Experiment 6 Set the Experiment Time 7 Preset Each Channel s Perfusion Time 7 Saving Your Experimental Parameters 9 Mode Selection 9 Co...

Страница 4: ...ii World Precision Instruments...

Страница 5: ...nfluence of metal ions in the moving iron of the solenoid valve on the experimental results Unlike other perfusion systems on the market which often compromise performance to fit every possible applic...

Страница 6: ...me is less than 100 nL The injection molded manifold is also designed as an economical disposable item eliminating problems of cross contamination from other experiments Notes and Warnings NOTE Before...

Страница 7: ...0mL Syringes 10 3 way Stopcock 10 Luer fitting with barb for 1 16 ID tubing 5 Color Coded Polyurethane Tubing Ribbon 1 manifold Holding Rod 1 manifold with 100 m ID tip 1 manifold with 250 m ID tip 1...

Страница 8: ...of this manual INSTRUMENT DESCRIPTION Hardware Installation 1 Set the MPS 4 perfusion stand on a stable platform 2 Insert the stainless steel post into the base and tighten the screw 3 Loosen the scre...

Страница 9: ...TING INSTRUCTIONS Fig 3 The front panel of the MPS 4 has the operational controls The left section of the MPS 4 front panel contains the Start Reset and Mode buttons and three functional indicator LED...

Страница 10: ...install an unsigned driver on Windows 8 on page 19 Appendix D Install the MPS 4 software on Windows 10 on page 22 Startup The perfusion software can be found in the Start menu of Windows under C Prog...

Страница 11: ...with the keyboard Move to the next field by filling in both digits of the field or by pressing the spacebar Click Apply when all fields are set to the desired values The perfusion time shown at the ri...

Страница 12: ...el click Apply to verify the changes Otherwise the new values will be lost when a different channel is chosen or the Setup window closes 5 You can also set the perfusion time by holding the left mouse...

Страница 13: ...der to change the operation mode or choose the serial port choose Mode Setup from the Operation menu press the F3 function key or click the button in the Tool Box The Mode Setup window pops up Click o...

Страница 14: ...on The button runs the perfusion process In the Online mode it acts as the button and runs the experiment controlled by the perfusion software In Offline mode the Start button runs the preset perfusio...

Страница 15: ...de Press any of the Channel keys if the experiment has to be manually halted This will exit out of TTL Control mode and prevent it from going back into that mode until Reset is pressed or the instrume...

Страница 16: ...t the tip of the micro perfusion head is close to the bottom of the dish The access angle is about 35 45 5 Pull a 1 m micropipette Fill the pipette with 150mM NaCl solution to make it a microelectrode...

Страница 17: ...lush it CAUTION Unfiltered water could clog the manifold and permanently damage it The manifold is made of PMMA material It can only be washed with water Any organic solvent even alcohol can permanent...

Страница 18: ...210x170 mm APPENDIX A DETERMINING FLOW RATE Theoretical Calculation The relationship of flow rate to the height of the liquid column and inner diameter of the capillary tubing can be accurately predic...

Страница 19: ...driver Please follow those steps below 1 Since you need to restart the computer multiple times during the operation you need to save your unfinished work and exit all applications before the disable d...

Страница 20: ...uments 3 Click the option Update security and a new window appears Fig 14 Select the Recovery tab 4 After selecting the Recovery tab the Advanced startup area appears on the right side of the window F...

Страница 21: ...restart 6 After restart the Option screen displays Fig 16 Click Troubleshoot 7 After clicking the option Troubleshoot the Troubleshoot screen appears Fig 17 Click Advanced Options 8 Click the option...

Страница 22: ...again The following menu appears on the screen after the restart Fig 20 Press 7 on your keyboard 11 You can press 7 on your keyboard to choose the Disable driver signing enforcement The computer will...

Страница 23: ...low the steps shown below to start Windows 8 in Disable Driver Signature Enforcement mode 1 Move the cursor over the top or bottom right corner or the screen and it will show extra options on the righ...

Страница 24: ...n the left hand side and then click Restart now button on the right Fig 23 Select the General tab and click Restart now 4 After a restart click Troubleshoot Fig 24 Select the Troubleshoot option 5 Cli...

Страница 25: ...Fig 27 Press Restart 8 Choose the Disable Driver Signature Enforcement and hit the Enter key to start Windows Fig 28 Select the Disable Driver Signature Enforcement option and press Enter 9 You shoul...

Страница 26: ...e click on it to begin the installation 3 Using the provided USB cable connect the USB port of host computer to the USB port square of the MPS 4 controller and then turn on the power of the MPS 4 cont...

Страница 27: ...on your computer depending on what is installed on your computer When the device manager is opened the Other devices Unknown device with yellow background exclamation mark will appear in the director...

Страница 28: ...nts 7 Click the Update Driver button The following window appears Fig 33 Select the option to Browse my computer 8 Select and click Browse my computer for driver software A similar window appears Fig...

Страница 29: ...from running MPS 4 19 07 exe during the installation For example on the this computer the MPS 4 program was specified to be installed in the following directory location C Program Files x86 MPS 4 Dri...

Страница 30: ...ver software was installed from running MPS 4 19 07 exe in step 2 Click the Next in the lower right corner and the following window appears Fig 38 Click the Install option 13 Select and click the Inst...

Страница 31: ...ontrollers section and confirm a successful installation of the driver software NOTE After the installation of the MPS 4 driver software a system reboot automatically resumes the state of the driver s...

Страница 32: ...28 World Precision Instruments...

Страница 33: ...MPS 4 World Precision Instruments 29...

Страница 34: ...30 World Precision Instruments...

Страница 35: ...ecial or consequential arising from a failure of this product to operate in the manner desired by the user WPI shall not be liable for any damage to data or property that may be caused directly or ind...

Страница 36: ...n Germany Tel 49 0 6031 67708 0 Fax 49 0 6031 67708 80 E mail wpide wpi europe com China Hong Kong WPI Shanghai Trading Co Ltd Rm 27A Liangfeng Building No 8 Dongfang Road Pudong Free Trade Zone Shang...