background image

EZ Anesthesia

World Precision Instruments 

1

ABOUT THIS MANUAL

The following symbols are used in this guide:

This symbol indicates a CAUTION. Cautions warn against actions that can cause 

damage to equipment. Please read these carefully.

This symbol indicates a WARNING. Warnings alert you to actions that can cause 

personal injury or pose a physical threat. Please read these carefully.

NOTES and TIPS contain helpful information.

INTRODUCTION

THIS MANUAL MUST BE READ BEFORE SETTING UP AND OPERATING THE EZ-

ANESTHESIA SYSTEM.  The user should be thoroughly familiar with the contents of this 

manual prior to using the system with animals.
Only technicians that are properly certified to use Isoflurane vaporizer and anesthetic 

equipment should operate the EZ-Anesthesia system.
The user/owner of this equipment shall have the sole responsibility for any damage 

or injury resulting from operation that is not in accordance with the authorized 

instructions.  This includes, but is not limited to, operating the equipment outside of 

recommended safety levels, variation from specified operating instructions and not 

following standard laboratory safety procedures when working with anesthetic agents 

and volatile compressed gases.  
The system and its components must only be modified or repaired by authorized 

service technicians. Improper modification or repair may result in danger to 

personnel, harm or death to animal, or equipment damage. The user/owner of this 

equipment shall have the sole responsibility for any damage or injury resulting from 

improper maintenance and repair that is not done by authorized maintenance and 

repair personnel. Contact WPI technical support for an list of authorized service 

technicians (941.371.1003/[email protected]).
Parts that have failed, in whole or in part, exhibit excessive wear, are contaminated 

or are otherwise at the end of their useful life, should not be used and should be 

replaced with replacements parts supplied by WPI.
Opening the vaporizer unit by unauthorized personnel automatically voids all 

warranties and specifications.  The manufacturer assumes no responsibility for any 

malfunction or failure of the unit if the seal is broken.  Do not open or remove screws 

that secure cover on the water pump unit.  Doing so may create electric shock hazard 

and will void all warranties and specifications on the unit.

Содержание EZ Anesthesia

Страница 1: ...WORLD PRECISION INSTRUMENTS EZ Anesthesia Serial No _____________________ www wpiinc com INSTRUCTION MANUAL 043019...

Страница 2: ......

Страница 3: ...ree Phases 3 Anatomy of an Anesthesia System 3 SETUP PROCEDURES 4 Water Pump And Surgical Pump Setup 5 Isoflurane Vaporizer Setup 5 Cautions and Warnings 5 Filling the Vaporizer 6 OPERATING THE SYSTEM...

Страница 4: ...ii World Precision Instruments...

Страница 5: ...ting instructions and not following standard laboratory safety procedures when working with anesthetic agents and volatile compressed gases The system and its components must only be modified or repai...

Страница 6: ...ygen Regulator Flow Meter 1 Vaporizer Manifold Flow Meter 2 Induction Chamber Oxygen Flush Charcoal Filter Canister Charcoal Filter Canister Breathing Device Nose cone Surgical Bed Water Heating Pump...

Страница 7: ...g liquid to create an anesthetic gas at the exact concentration level required Manifold distributes anesthetic gas to the induction chamber and the breathing devices Flowmeter 2 controls the flow rate...

Страница 8: ...induction chamber input B Attach air filter canister to the white plastic filter adaptor at the end of the large diameter exhaust line coming from the chamber C Slide the air filter canister onto the...

Страница 9: ...ls below the indicator line turn off the pump remove cap and add water up to the indicator line Do not exceed the indicator line level Replace the cap and operate the pump Repeat steps 4 and 5 until t...

Страница 10: ...vaporizer upright at all times and do not carry the vaporizer by holding the dial control Filling the Vaporizer 1 The control dial must be in OFF position Press the lock button to turn the dial Alway...

Страница 11: ...g and surgical bed is at proper temperature WARNING IMPORTANT MAKE SURE THE SMALL BLACK PLUG IS INSERTED INTO BREATHING DEVICE NOSECONE THE OPERATOR COULD FACE EXPOSURE TO ISOFLURANE IF THE PLUG IS NO...

Страница 12: ...e moved to the breathing unit be sure that the desired breathing units are connected to the manifold 2 Reduce the secondary flowmeter setting to zero then press the oxygen flush button for 5 10 second...

Страница 13: ...o appropriately marked containers and disposed of properly Less frequent intervals may be used when the anesthetic agent does not contain additives or a stabilizing agent CAUTION Do not drain the vapo...

Страница 14: ...e top of the water pump and tip the pump over a sink until all the water is emptied from the pump 3 Replace the cap on the pump Disinfecting the Water Pump and Surgical Bed The water pump and surgical...

Страница 15: ...t special or consequential arising from a failure of this product to operate in the manner desired by the user WPI shall not be liable for any damage to data or property that may be caused directly or...

Страница 16: ...berg Hesson Germany Tel 49 0 6031 1602171 Fax 49 0 6031 1602180 E mail wpide wpi europe com China Hong Kong WPI Shanghai Trading Co Ltd Rm 18A No8 Dongfang Rd Pudong District Shanghai 200120 PR China...

Отзывы: