APOLLO 4000
WORLD PRECISION INSTRUMENTS
3
Copyright © 2003 by W
orld Pr
ecision Instr
uments, Inc. All rights r
eserved. No par
t of this publication may be r
epr
oduced or translated into
any language, in any for
m, without prior written per
mission of W
orld Pr
ecision Instruments, Inc.
Contents
INTRODUCTION ............................................................................... A-1
Design Architecture ........................................................................................ A-2
Plug-and-Play Design ..................................................................................... A-2
Free Radical Sensor Technology .................................................................... A-2
Instrument Description ................................................................................... A-3
Unpacking ...................................................................................................... A-5
OPERATING INSTRUCTIONS ........................................................... B-1
Setting up the APOLLO 4000 ......................................................................... B-1
APOLLO.EXE Operating Software .................................................................. B-4
Example of a real signal application ............................................................ B-12
USING THE APOLLO 4000 TO DETECT NITRIC OXIDE ................... C-1
Initial Set-up .................................................................................................... C-1
Calibration of the NO Sensor .......................................................................... C-1
The Calibration Kit .......................................................................................... C-1
Calibration by the chemical generation of NO ............................................... C-2
Calibration of NO sensor by decomposition of SNAP .................................... C-7
Calibration of NO sensor using aqueous standards prepared with NO Gas C-15
Measurement of NO ..................................................................................... C-18
Maintenance of NO Sensors ........................................................................ C-20
USING THE APOLLO 4000 TO DETECT OXYGEN ............................ D-1
Initial Set-up .................................................................................................... D-1
Calibration and Use of Oxygen Sensors ........................................................ D-1
Calibration ...................................................................................................... D-2
Probe Structure and Assembly ....................................................................... D-8
USING THE APOLLO 4000 TO DETECT HYDROGEN PEROXIDE ..... E-1
Initial Set-up ..................................................................................................... E-1
The structure of the HPO sensor ..................................................................... E-1
Calibration of the HPO Sensor ........................................................................ E-2
Calibration Procedure ...................................................................................... E-2
Interference ..................................................................................................... E-4
Maintenance of HPO Sensors ......................................................................... E-4
TROUBLESHOOTING FOR APOLLO 4000 ........................................ F-1
APPENDIX: BASIC GROUNDING & SHIELDING PRINCIPLES ........ G-1
Содержание APOLLO 4000
Страница 2: ......
Страница 4: ......
Страница 10: ...APOLLO 4000 INTRODUCTION WORLD PRECISION INSTRUMENTS A 6...
Страница 48: ...APOLLO 4000 NITRIC OXIDE DETECTION WORLD PRECISION INSTRUMENTS C 24...
Страница 70: ...APOLLO 4000 TROUBLESHOOTING WORLD PRECISION INSTRUMENTS F 2...
Страница 72: ......
Страница 74: ......