P1-DC: #35111
Rev 29.0/11-19
16
Controlling the Lifter and Load
1A
When the lifter is ready, use the hoisting equipment to raise
the lifter and load as needed.
Use the control handle (circled in fig. 1A) to keep the lifter
and load in the required position.
Once there is enough clearance, you may move the load as
required.
In Case of a Power Failure
A vacuum reserve tank helps maintain vacuum temporarily in the event of a battery failure or
electrical system failure. Although the lifter is designed to support the load for at least 5
minutes without power, this depends on many factors, including the “L
” on
page 9 and the condition of the vacuum pads (see “V
Stay clear of any suspended
load during power failure.
If a power failure occurs, keep everyone away from a
suspended load until it can be safely lowered to a stable
support. Correct any faults before resuming normal
operation of the lifter.
OPERATION
Содержание P110C04DC
Страница 2: ...P1 DC 35111 Rev 29 0 11 19 2...
Страница 6: ...P1 DC 35111 Rev 29 0 11 19 4 SPECIFICATIONS Note A standard P11104DC is shown...
Страница 32: ...P1 DC 35111 Rev 29 0 11 19 30...
Страница 33: ...Rev 29 0 11 19 P1 DC 35111 31...
Страница 34: ...P1 DC 35111 Rev 29 0 11 19 32...
Страница 35: ......
Страница 36: ......