ConnectionHostAddr
Valid values:
Any valid IP address or web site address (URL)
Function: Set to
www.worthdata.net/connect/server.php
by default for standard internet operation.
Do not change unless you know exactly what you are doing. If you are not familiar with
IP addresses and URLs, leave this value at the default setting.
ConnectionHostPort
Valid values:
1-65536
Function: Set to 80 by default for standard internet operation. Do not change unless you know
exactly what you are doing. If you are not familiar with IP ports, leave this value at the
default setting.
Username
Valid values:
Any alpha-numeric combination up to 12 characters
Function: Part of Application Server access key system. In order to connect with an Application
Server, settings for Username, Server ID, and Password must all be set identically in the
Application Server and all Terminals that use this Application Server.
ServerID
Valid values:
Any alpha-numeric combination up to 12 characters
Function: Part of Application Server access key system. In order to connect with an Application
Server, settings for Username, Server ID, and Password must all be set identically in the
Application Server and all Terminals that use this Application Server.
Password
Valid values:
Any alpha-numeric combination up to 12 characters
Function: Part of Application Server access key system. In order to connect with an Application
Server, settings for Username, Server ID, and Password must all be set identically in the
Application Server and all Terminals that use this Application Server.
InternalPolling
Valid values:
True, False
Function: Default value is True. Set InternalPolling to True to instruct the ActiveX control to poll
the Connection Host for incoming data. Some environments, like Visual Basic and
Excel do not work with internal polling and you must set InternalPolling to False and
set up a timer in your application to drive Server polling through calls to the PollServer
method (see below).
PollInterval
Valid values:
50-5000
Function: Default value is 1000. Sets the server polling cycle time in milliseconds. Setting a
shorter interval, such as 200 or 500 mSec will speed up the terminal response time but
increase your network traffic. This setting is ignored if InternalPolling is false.
ServerActive
Valid values:
True, False
Function: Set ServerActive to True to begin listening for terminals. Before setting to True, be sure