background image

      value  data  by  turning  the  volume  (1).  When  modifying  P05  and  P06,  move  to  the  percentage           

      value  with  the  F2  button  and    you  can  change  the  data  by  the  volume  (1) 

■  Hidden  data  adjustments  /  modifiable  data  items

No

Item

Setting  range

Minimum

Reset

Factory  set

P01

Burn  back  time

0.01-2.00s

0.01s

0.08s

0.03s

P02

Motor  speed  on  open  circuit 

voltage

1.0-21.0M/min

0.1M/min

3.0M/min

3.0M/min

P03

Pre-flow  time

0.1-10.0s

0.1s

0.20s

0.20s

P04

Post-flow  time

0.1-10.0s

0.1s

1.0s

2.0s

P05

Start  current

1-200%

1%

135%

100%

P06

Crater  current

1-200%

1%

50%

30%

P07

Up-down  slope  time

0.1-10.0s

0.1s

2.0s

2.0s

P08

Spot  time

0.5-5.0s

0.1s

2.0s

2.0s

P09

Remote  control  on/off

OFF/ON

OFF

OFF

P10

Water  cooling  on/off

OFF/ON

ON

OFF

P11

Double  pulse  frequency

0.5-5.0Hz

0.1Hz

OFF

3.3

P12

Double  pulse  arc  length

-50-+50

1

0.0

1.0

P13

Double  pulse  speed 

0-2m

0.1m

2.0m

2.0m

P14

Double  pulse  width

10-90%

1%

50%

50%

P15

Single  pulse  frequency

OFF/UI/UU/II

OFF

UU

P16

Fan  delay  time

5-15min

1min

15min

15min

P17

Up-slope  time

0-10S

1S

OFF

0.1

P18

Down  slope  time

0-10S

1S

OFF

OFF

P19

Synergic  /  Individual  mode 

on/off

OFF/ON

ON

ON

Note:  If  you  press  the  volume  (1)  for  about  3  seconds,  the  welder  will  be  set  to  the  initial  state.

If  an  error  occurs  during  operation,  the  welder  is  automatically  protected  and  the  error  code  is 

displayed  on  the  digital  window  with  the  code  number.

Содержание Longrun 500LMP

Страница 1: ...sumption by high tech IGBT Ideal to weld stainless steel and aluminum Model Unit 500LMP Input voltage V 380V 3PH 50 60Hz Output current A 25 500 Input capacity KVA 25 Input current A 46A Open circuit...

Страница 2: ...s and gases away from the breathing zone Use enough forced ventilation or local exhaust forced suction at the arc to remove the fumes from your breathing area Wear complete body protection Wear oil fr...

Страница 3: ...the cover of terminal plate For grounding the machine connect a ground wire to the ground terminal marked with the symbol is located on the rear panel of the machine Connect a power cord of gas regula...

Страница 4: ...CrNi 188 4CrNi 199 0 8 1 0 1 2 1 6 304 308 309 316 97 5 Ar 2 5 CO2 Mild steel 2 Steel E70 82 Ar 18 CO2 Silicon copper Alloy 6 CuSi 1 2 1 6 HS211 100 Ar Aluminum Copper Alloy 5 CuAl 1 0 1 2 1 6 HS214 1...

Страница 5: ...FRONT PANEL...

Страница 6: ...temperature LED 16 Arc Power Arc Concentration It shows that arc power adjustment during MIG MAG pulse welding arc power decrease 0 standard arc power increase In MIG MAG welding arc concentration is...

Страница 7: ...0 1s 2 0s 2 0s P08 Spot time 0 5 5 0s 0 1s 2 0s 2 0s P09 Remote control on off OFF ON OFF OFF P10 Water cooling on off OFF ON ON OFF P11 Double pulse frequency 0 5 5 0Hz 0 1Hz OFF 3 3 P12 Double puls...

Страница 8: ...the cable 2 Replace the volume of wire feeder E30 Wire feeder overload 1 Welding wire is finished 2 Motor overload Motor Failure 1 Replace with new welding wire 2 Replace motor E15 Power supply error...

Страница 9: ...mber Date Purchased Where Purchased Where you use Whenever you request replacement parts or information on this machine always supply the information you have recorded above The date number is especia...

Отзывы: