value data by turning the volume (1). When modifying P05 and P06, move to the percentage
value with the F2 button and you can change the data by the volume (1)
■ Hidden data adjustments / modifiable data items
No
Item
Setting range
Minimum
Reset
Factory set
P01
Burn back time
0.01-2.00s
0.01s
0.08s
0.03s
P02
Motor speed on open circuit
voltage
1.0-21.0M/min
0.1M/min
3.0M/min
3.0M/min
P03
Pre-flow time
0.1-10.0s
0.1s
0.20s
0.20s
P04
Post-flow time
0.1-10.0s
0.1s
1.0s
2.0s
P05
Start current
1-200%
1%
135%
100%
P06
Crater current
1-200%
1%
50%
30%
P07
Up-down slope time
0.1-10.0s
0.1s
2.0s
2.0s
P08
Spot time
0.5-5.0s
0.1s
2.0s
2.0s
P09
Remote control on/off
OFF/ON
OFF
OFF
P10
Water cooling on/off
OFF/ON
ON
OFF
P11
Double pulse frequency
0.5-5.0Hz
0.1Hz
OFF
3.3
P12
Double pulse arc length
-50-+50
1
0.0
1.0
P13
Double pulse speed
0-2m
0.1m
2.0m
2.0m
P14
Double pulse width
10-90%
1%
50%
50%
P15
Single pulse frequency
OFF/UI/UU/II
OFF
UU
P16
Fan delay time
5-15min
1min
15min
15min
P17
Up-slope time
0-10S
1S
OFF
0.1
P18
Down slope time
0-10S
1S
OFF
OFF
P19
Synergic / Individual mode
on/off
OFF/ON
ON
ON
Note: If you press the volume (1) for about 3 seconds, the welder will be set to the initial state.
If an error occurs during operation, the welder is automatically protected and the error code is
displayed on the digital window with the code number.