Worldwel Longrun 500LMP Скачать руководство пользователя страница 8

■  Symptom  and  solution 

Code  no. 

Symptoms

Cause 

Solution

E40

Communication  error 

between  Main  PCB 

and  Display  PCB

1.  Cable  failure

2.  Main  PCB  failure

1.  Check  and  replace  the  cable

2.  Replace  the  Main  PCB

E41

Wire  feeder 

communication  error 

1.  Cable  failure

2.  Wire  feeder  PCB  failure

1.  Check  and  replace  the  cable

2.  Replace  the  Wire  feeder  PCB

E42

Communication  error 

between  the  welder 

and  wire  feeder

1.  Connect  failure  between  the  welder  and 

wire  feeder

2.  Internal  cable  failure

3.  Wire  feeder  PCB  failure

4.  Main  PCB  failure

1.  Check  the  cable  in  Wire  feeder  and 

the  welder

2.  Check  and  replace  the  internal  cable

3.  Replace  Wire  feeder  PCB

4.  Replace  Main  PCB

E33

Welding  wire  stick  to 

base  metal 

At  the  end  of  welding,  welding  wire  sticks 

to  base  material

Turn  off  the  main  power  and  detach 

welding  wire  from  base  metal. 

E34

Input  error  of  Wire 

feeder

1.  Cable  failure

2.  Welding  voltage  and  current  volume 

failure  in  Wire  feeder. 

1.  Check  and  replace  the  cable

2.  Replace  the  volume  of  wire  feeder. 

E30

Wire  feeder  overload

1.  Welding  wire  is  finished. 

2.  Motor  overload,  Motor  Failure. 

1.  Replace  with  new  welding  wire

2.  Replace  motor

E15

Power  supply  error

1.  Torch  switch  pressed  at  power-on

2.  Open  circuit  voltage  error

3.  Current  detected

4.  Welding  wire  is  fed

5.  Gas  detected

1.  Release  torch  switch 

2.  Check  that  Output  cable  is  short 

circuit. 

E17

Over  current

1.  Over  current 

2.  Hole  sensor  failure

3.  Signal  cable  disconnected

4.  Main  PCB  failure

1.  Check  main  circuit

2.  Supply  input  power 

3.  Check  signal  cables

4.  Replace  Main  board

E18

Output  voltage  error

1.  Voltage  feedback  cable  got  damaged

2.  Main  pcb  failure

1.  Check  Voltage  feedback  cable  and 

replace  it

2.  Replace  Main  board

E19

Temperature  protect

1.  Overheat  in  side  of  welding  machine 

2.  Temperature  sensor  fault

3.  Signal  cable  failure

4.  Main  pcb  failure

1.  Check  the  ventilation  and  follow 

duty  cycle  of  machine

2.  Replace  temp.  sensor

3.  Check  Signal  cables

4.  Replace  Main  pcb

E10

Torch  switch  error

No  weld  even  pressing  torch  switch  for  a 

long  time

Torch  switch  off

E88

Motor  don’t  work

Motor  board  failure

Check  and  replace  Wire  feeder  board 

Содержание Longrun 500LMP

Страница 1: ...sumption by high tech IGBT Ideal to weld stainless steel and aluminum Model Unit 500LMP Input voltage V 380V 3PH 50 60Hz Output current A 25 500 Input capacity KVA 25 Input current A 46A Open circuit...

Страница 2: ...s and gases away from the breathing zone Use enough forced ventilation or local exhaust forced suction at the arc to remove the fumes from your breathing area Wear complete body protection Wear oil fr...

Страница 3: ...the cover of terminal plate For grounding the machine connect a ground wire to the ground terminal marked with the symbol is located on the rear panel of the machine Connect a power cord of gas regula...

Страница 4: ...CrNi 188 4CrNi 199 0 8 1 0 1 2 1 6 304 308 309 316 97 5 Ar 2 5 CO2 Mild steel 2 Steel E70 82 Ar 18 CO2 Silicon copper Alloy 6 CuSi 1 2 1 6 HS211 100 Ar Aluminum Copper Alloy 5 CuAl 1 0 1 2 1 6 HS214 1...

Страница 5: ...FRONT PANEL...

Страница 6: ...temperature LED 16 Arc Power Arc Concentration It shows that arc power adjustment during MIG MAG pulse welding arc power decrease 0 standard arc power increase In MIG MAG welding arc concentration is...

Страница 7: ...0 1s 2 0s 2 0s P08 Spot time 0 5 5 0s 0 1s 2 0s 2 0s P09 Remote control on off OFF ON OFF OFF P10 Water cooling on off OFF ON ON OFF P11 Double pulse frequency 0 5 5 0Hz 0 1Hz OFF 3 3 P12 Double puls...

Страница 8: ...the cable 2 Replace the volume of wire feeder E30 Wire feeder overload 1 Welding wire is finished 2 Motor overload Motor Failure 1 Replace with new welding wire 2 Replace motor E15 Power supply error...

Страница 9: ...mber Date Purchased Where Purchased Where you use Whenever you request replacement parts or information on this machine always supply the information you have recorded above The date number is especia...

Отзывы: