background image

■  WIRE  TYPE  SELECT

Process

Wire  type

Diameter(mm)

Alloy  type

Sheild  gas

MIG/MAG

Pulse  welding

Aluminum

Magnesium  Alloy

(8  AlMg  5)

Φ1.0,  Φ1.2,  Φ1.6

LF2~LF16,  5005,  5052, 

5183,  5356

100%  Ar

Aluminum

(9  Al)

L1~L5, 

1060,  1035,  1100,  1200, 

1370

Aluminum

Silicon  Alloy

(7  AlSi  5)

LT1,  4A11,  4043,  4047

Stainless  steel

(3CrNi  188)
(4CrNi  199)

Φ0.8,  Φ1.0,  Φ1.2, 

Φ1.6

304,  308,  309,  316

97.5%  Ar+2.5%CO

2

Mild  steel

(2  Steel)

E70

82%  Ar+18%  CO

2

Silicon  copper 

Alloy

(6  CuSi)

Φ1.2,  Φ1.6

HS211

100%  Ar

Aluminum

Copper  Alloy

(5  CuAl)

Φ1.0,  Φ1.2,  Φ1.6

HS214

100%  Ar

MIG/MAG

Welding

Mild  steel

(1  Steel)

Φ0.8,  Φ1.0,  Φ1.2, 

Φ1.6

E70

100%  CO

2

82%  Ar

+18%CO

2

■  Input  cable 

Model

Pulse  MIG-500

Input  power

380V,  3PH

Ideal  Input 

capacity

Normal

38KVA

Generator

50KVA

Input  protect

Fuse

50A

Circuit 

breaker

63A

Cable

Input  power 

≥6mm2

Output 

power

70mm2

Ground  cable

≥6mm2

Содержание Longrun 500LMP

Страница 1: ...sumption by high tech IGBT Ideal to weld stainless steel and aluminum Model Unit 500LMP Input voltage V 380V 3PH 50 60Hz Output current A 25 500 Input capacity KVA 25 Input current A 46A Open circuit...

Страница 2: ...s and gases away from the breathing zone Use enough forced ventilation or local exhaust forced suction at the arc to remove the fumes from your breathing area Wear complete body protection Wear oil fr...

Страница 3: ...the cover of terminal plate For grounding the machine connect a ground wire to the ground terminal marked with the symbol is located on the rear panel of the machine Connect a power cord of gas regula...

Страница 4: ...CrNi 188 4CrNi 199 0 8 1 0 1 2 1 6 304 308 309 316 97 5 Ar 2 5 CO2 Mild steel 2 Steel E70 82 Ar 18 CO2 Silicon copper Alloy 6 CuSi 1 2 1 6 HS211 100 Ar Aluminum Copper Alloy 5 CuAl 1 0 1 2 1 6 HS214 1...

Страница 5: ...FRONT PANEL...

Страница 6: ...temperature LED 16 Arc Power Arc Concentration It shows that arc power adjustment during MIG MAG pulse welding arc power decrease 0 standard arc power increase In MIG MAG welding arc concentration is...

Страница 7: ...0 1s 2 0s 2 0s P08 Spot time 0 5 5 0s 0 1s 2 0s 2 0s P09 Remote control on off OFF ON OFF OFF P10 Water cooling on off OFF ON ON OFF P11 Double pulse frequency 0 5 5 0Hz 0 1Hz OFF 3 3 P12 Double puls...

Страница 8: ...the cable 2 Replace the volume of wire feeder E30 Wire feeder overload 1 Welding wire is finished 2 Motor overload Motor Failure 1 Replace with new welding wire 2 Replace motor E15 Power supply error...

Страница 9: ...mber Date Purchased Where Purchased Where you use Whenever you request replacement parts or information on this machine always supply the information you have recorded above The date number is especia...