10. ADMINISTRATOR MODE
10.6 Outputs Settings
Here is the settings for digital outputs. The number of rows depends on the ROI’s setting from tab Alarm Settings.
There are up to 7 digital outputs.
There is also special testing mode, that can be activated by clicking the button ”Test mode”.
Figure 10.13: Outputs settings.
10.6.1 Digital Outputs
Pulse
Set the length for the signal pulse in milliseconds. This is the minimal length of the signal that will be produced
after the signal occurs. When the alarm ends, the signal will still be outputted for the set length.
Edge
Select the edge of a signal. Either the edge is rising or falling.
Rising edge has the nonactive state at zero and the signal is a change between zero to the supply voltage, thus
the voltage is rising.
Falling edge has the nonactive state at supply voltage and the signal is a change between supply voltage to zero,
thus the voltage is falling.
(a) Rising edge.
(b) Falling edge.
Figure 10.14: The difference between signals rising and falling edge.
Test
Clicking the button in Test mode will produce the set signal according to its edge and length of pulse.