7. SYSTEM ASSEMBLY
7
System assembly
7.1 Connection
For fully controlling the SAFETIS you need:
Ethernet Cable
1x M12 5‐pin cable for power supply (Safetis indoor only)
1x M12 8‐pin cable for Digital Outputs
7.1.1 Power Supply
7.1.1.1 SAFETIS Indoor Power Supply
You can power your SAFETIS with M12 5‐pin cable. Voltage between VCC and GND pins must be within range
18VDC ‐ 32VDC
. You can see the power connector pinout in the Figure 7.1a.
(a) Power supply connector
pinout.
Contact
Function
Color
1
VCC+
Brown
2
VCC+
White
3
GND
Black
4
GND
Blue
5
NC
Gray
(b) Power supply wire coloring.
Note
: Exceeding the input power range may cause damage to the SAFETIS.
SAFETIS Indoor has power consumption 10W.
E‐mail and Web
[email protected]
www.workswell.eu
Mobile:
+420 725 877 063
ID:
Reg. No.: 29048575
VAT No.: CZ29048575
Headquarters
U Albrechtova vrchu 12
155 00, Prague 13
Czech Republic
Version 210224 EN, 24
th
Feb, 2021
All pictures are only for illustration.
Real values may vary.
11