VI. OPERATION
1.
Place your
TO-A02
Drive Fitting completely into/over the Trailer Trap to be
opened or closed.
2.
Ensure the torque reaction area of movement is taken up by the Reaction Arm.
Also, ensure the Reaction Arm is stable and will support counter torque.
3.
Hold the
TO-A02
perpendicular to the Trap's Capstan for the complete duration
of the rotation process to open or close the Trap.
IMPORTANT
Because of the high mechanical stress on the
TO-A02
Opener, it is essential to provide the FRL Unit with
sufficient oil supply, to reduce the risk of damaging
the vanes of the air motor. Adjust the oil feed on the
FRL’s Lubricator to 2 to 3 drops per-minute for regular
equipment use.
CAUTION
Do NOT Exceed Maximum Regulator Pressure setting
for type of Trailer Trap being opened. Damage will
occur if excess PSI is used.
CAUTION
Experience shows that a Regulator setting of 20
to 21 PSI (140 to 145 ft-lbf force) is all that is
required to open Strap-type Trailer Traps. Rack
and Pinion type Trailer Traps may require a
Regulator setting of 30 to 40 PSI (244 to 250
ft- lbf force) to open.