Maintenance
3730 E. Southern Avenue, Phoenix, AZ 85040 USA
800-778-8779
Workhorseproducts.com
13
Cleaning the Glass
Disconnect the power before servicing the PhotoSharp.
To clean the under side of the glass, remove the two
screws located on either side of the front panel.
Remove the front panel and set it aside.
Using lint free rags or paper towel, spray the glass
cleaner directly on the towel and while reaching
through the front panel access hole clean the bottom
surface on the glass.
Replacing the Bulbs
The 1000 watt metal halide lamp is a high energy lamp that will create a very even exposure across the print
area. This is a pin point light source that will result in sharp defined edges of the exposed design.
Extreme caution must be taken when replacing the 1000 watt metal halide lamp.
Always unplug the power
cord from the wall before attempting any maintenance or replacing the lamp.
The 1000 watt metal halide lamp outputs a high level of UV radiation,
which can cause eye and skin damage
.
Never attempt to operate the PhotoSharp with the drawer or top open. The PhotoSharp exposure unit is
equipped with safety features that will prevent the lamp from illuminating when the drawer or top is open.
1. Always unplug the power cord from the wall before
attempting any maintenance or before replacing the
lamp.
Open the bottom drawer by removing the two screws to
access the light source.
The light source will stay closed when the lamp is not
illuminated. The shutter will open when the exposure
cycle begins and will close to end the exposure cycle.
Never attempt to operate the PhotoSharp when the
drawer is open.