DISPLAY INFORMATION
6 720 648 726 (2011/07)
78
e
[a/0/1|
e
[8/1/1|
e
Fault:
Thermal disinfection has failed. Outlet flow
during disinfection period too high, sensor
lead broken or shorted, sensor connected
incorrectly or defective, filling pump
defective.
No
Off
Thermal disinfection
was interrupted.
e
[a/0/1|
e
[8/1/6|
e
Fault:
No connection to EMS. EMS bus system is
overloaded, UBA3/MC10 is defective.
No
Off
The boiler no longer
receives a heat
demand. The heating
system does not
heat any longer.
e
[a/0/1|
e
[8/2/8|
e
Fault:
Water pressure sensor generates a fault
code. The digital water pressure sensor is
defective.
No
Off
No heating operation
and no DHW.
e
[a/0/2|
e
[8/1/6|
e
Fault:
No communication with BC10. Contact
problem at BC10 or BC10 is defective.
No
Off
BC10 settings are no
longer taken over by
RCxx devices.
e
[a/1/1|
e
[8/0/2|
e
Fault:
Time not set. Failing time setting, e.g. due to
a long power cut.
No
Off
Limited operation of
all heating programs
and fault list.
e
[a/1/1|
e
[8/0/3|
e
Fault:
Date not set. Failing date setting, e.g. due to
a long power cut.
No
Off
Limited operation of
all heating programs,
holiday function,
fault list.
e
[a/1/1|
e
[8/2/1|
e
Fault:
RC35-HK1 remote control. No remote
control assigned, although room
temperature control has been set.
No
Off
Since there is no
actual room
temperature
information, room
influence and
optimization of the
switch times do not
work. The EMS
works on the basis
of the values last set
on the remote
control.
e
[a/1/1|
e
[8/2/2|
e
Fault:
RC35-HK2 remote control. No remote
control assigned, although room
temperature control has been set.
Display codes
Display code
LED on
UBA 3
Other effects
z
Main
display
code
z
Sub
display
code
z
Key to display code
Reset
requi-
red?
Table 24 Display codes