Note: READ THIS SECTION FULLY BEFORE COMMENCING THE
INSTALLATION
11.1
General
The appliance is only suitable for fitting to a sealed system.
The flue must be installed as specified in BS5440:1.
11.2
Unpacking
Remove the appliance from its packaging and check the contents
against the packing list.
Lie the appliance on its back and undo the union connections on
the manifold assembly. Refer to Fig 16. Slide the appliance off the
wall mounting assembly.
11.3
Site Preparation
Check that the correct position for the appliance has been
chosen. Refer to Section 4 and Table 8.
Check that the wall is flat and will support the weight of the
appliance. Refer to Table 4.
11.4
Fixing Holes and Flue Opening
Hold the wall mounting assembly against the wall. Check that
the assembly is level. The diamond cut-out on the assembly
indicates the centre-line of the appliance.
Mark the position of the fixing holes and the flue opening. Refer
to Fig. 5 and 15.
Mark the centrelines of the pipe connections to aid the pre-
plumbing of the system pipework.
Check the position of the fixing points and flue opening before
drilling the fixing holes 60mm deep for the No. 12 size plugs and
cutting the flue duct hole at 110mm diameter [150mm diameter
for internally fitted flues].
11.5
Wall Mounting Plate and Manifold
Fit the plugs and insert the bottom screws. Offer the assembly to
the wall utilising the keyhole slots on the manifold assembly and
fix to the wall. Refer to Fig 15 and 16.
Check that the assembly is properly aligned before tightening
the screws.
11.6
Gas and Water Pipes
Remove the gas cock and fix the appropriate fitting to connect
the inlet pipe and refit. Refer Fig 16.
Pre-plumbing is not recommended if no movement in the pipes
is available.
If it is necessary for any of the pipes to run up the back of the
appliance then they must be arranged to pass behind the
expansion vessel. Refer to Fig 3. Pipework must not run
horizontally within the limits of the casing.
Support the valves when tightening the connections to prevent
distortion of the manifold assembly
It is important that the pipes are not fixed near the appliance
using clips that put a strain on the connections.
Before the appliance is fitted to the wall thoroughly
flush the system and mains water supply.
11. Installing The Appliance
12
Fig 13 - Replacement internal fuses
1
2
3
4
5
1. Fuse -F1 T2A 5. Clip on Facia cover
2. Fuse -F2 T1.6A
3. Connections Cover
4. Connections Cover Fixing
Screw
NOTE
: Check the size of the fuse before fitting
Earth
Green/Yellow
Blue
Neutral
Blue
L N
Fig.14 . Mains electricity connections.
230V
ST12
LR
E
Bottom Left Hand Side - Facia
Strain relief clamp
N LS
Live
Brown
Mains lead
External control
Fig.15 . Wall mounting assembly
20
▲
▲
218
▲
▲
75
540
▲
▲
▲
▲
▲
▲
60
60
65
338
797
Cabinet Height
800
367
All dimensions in mm