13.1
Hand the users instructions to the user or purchaser for
retention and instruct them in the efficient and safe operation of
the appliance and the heating/hot water system.
13.2
Advise the user or purchaser of the precautions necessary
to prevent damage to the heating/hot water system and to the
building in the event of the heating system remaining
inoperative during frost conditions.
13.3
Finally advise the user or purchaser that for continued
efficient and safe operation of the appliance it is important that
adequate servicing is carried out by a qualified engineer at least
once per year.
Worcester Heat Systems Limited will be pleased to discuss and
offer a comprehensive maintenance contract.
13.4
Set the system controls to the users requirements.
13. Instructions To The User
15
Fig. 16.
Location of Boiler Flueway Baffles.
(a) 50/70
ENSURE THAT ALL BAFFLES ARE FIRMLY SEATED IN POSITION
BAFFLE
RETAINER
BAFFLE
HEATSHIELD
(b) 70/90 and 90/110
Fig. 15. Electro Oil Sterling 40 Burner.
(90/110 model).
Ignition
transformer
Connecting
pipe
Solenoid
valve
Air control
indicator
Air adjustment
screw
(4mm hexagonal head)
Pressure
adjustment
screw
Photocell
Motor
Combustion head
Control
box
Pump
Lockout
reset button
Output
Combustion Head
Dimension
kW
A
26-32
PL 6/7/21.5/10 x 78 mm
3.5 mm
Combustion Head
Draught tube
Nozzle
Nozzle block
Spark gap
2.5 - 3.0mm
0mm
7.5mm
A
Содержание 70/90
Страница 19: ...19 NOTES ...