User manual
Treatment crush: SA0042
Version: 10 February 2021 08:02:46
Page 30 of 34
Changing oil
No.
What to do
Action
Result
1.
Bring the oil to the tank
See the instructions for “Checking the oil
level”
2.
Remove the plug from
the power source
Remove the plug from the power source
and make sure it cannot be plugged in.
The crush is not
electrified.
3.
Empty the tank
Open the valve for the tank and drain the
oil from the tank until it is empty.
The tank runs empty.
4.
Close the valve
Close the valve so no more oil can pass
through.
5.
Fill the installation
This must be done at the filter. First, clean
the outside of the cover and filter.
Remove the cover of the filter at the top of
the tank by unscrewing the bolts. Then
remove the cover and fill the tank at the
hole of the filter.
Use the correct oil. (see Figure 10)
6.
Check the oil level
Fill to the level shown in Figure 9.
7.
Install new filters
Replace the filters.
8.
Put cover in place
Install the cover and tighten it sufficiently.
The following types of oil are suitable for use in the hydraulic system:
Supplier
Oil
Castrol
HYSPIN AWH – M 32 / 46
Mobil
UNIVIS N 32 / 46
Q8
HANDEL 32 / 46
Q8
HELLER 32 / 46
Texaco
RANDO 32 / 46
Texaco
HYDRAULIC OIL HDZ 32 / 46
Total
EQUIVIS ZS 32 / 46
Valvoline
100 ULTRAMAX HVLP 32 / 46
Petronas
HYDRAULIC HV 32 / 46
Gulf
HARMONY HVI 32 / 46
Shell
TELLUS S2 V 32 / 46
Shell
TELLUS T 32 / 46
Figure 10: hydraulic oil to be used