Infrastructure Requirements
01/2019-v1.0en
17
4.4.5
Silicon Dust Compatibility
Due to hardware restrictions SiliconDust HD Homerun Extend is the only model that
is compatible with the ProSmart. For the SiliconDust to work it must receive one of
the following signal types:
•
ATSC: Standard over the air broadcast digital television (Antenna option)
•
QAM64/256: The headend system must output a QAM64/256 signal or the Sili-
conDust is not compatible.
Use the following flowchart to determine whether a SiliconDust is a viable option.
Fig. 4
Flowchart to determine whether a SiliconDust is a viable option
4.4.6
Data Networking Configuration Requirements
The administrator of your data network should ensure that the network meets the
following requirements to support ProSmart.
Outbound ports required to support full ProSmart Functionality:
•
TCP Port 80 (HTTP)
•
TCP Port 443 (HTTP)
•
UDP Port 123 (NTP)
•
Port 5100-5299, 5500 (VNC)
If the SiliconDust option is being used there are additional network requirements.
Connecting the SiliconDust to the treadmill requires knowing the IP Address that
has been assigned to the SiliconDust box. The SiliconDust does NOT support a stat-
ic IP Address. Instead, a DHCP Reservation based on the MAC Address will be re-
quired to keep a consistent connection to the treadmill.